Maintenance and Storage
Cleaning and Inspection Procedures
Several maintenance procedures are recommended for the MMP. Before deployment,
after recovery, and before and after storage, inspect the following:
O-rings
Bulkhead and cable connectors
Nylon and stainless steel hardware
Glass spheres
If you can immerse the MMP in fresh water, use warm water with soap or mild detergent
added to remove salt and other substances. Common soaps and detergents will not damage the
MMP. Do not use solvents.
IMPORTANT
Salt crystals can form on o-rings or o-ring sealing surfaces as seawater evaporates, leaving grit
that could cause leaks during your next deployment. Thoroughly rinsing the MMP with fresh
water immediately after recovery is a critical maintenance procedure to extend system life and
prevent future problems.
O-Rings
Both ends of the controller housing are sealed with face and radial o-rings. Inspect
o-rings for damage, wear, and foreign material before and after every deployment to prevent
flooding of the housing. Look for small cracks and feel for bumps, grit, or hair. After inspection,
ensure that the o-rings stay in position as the end cap is inserted into the cylinder. Spare o-rings
are included in the Toolkit. Part numbers are given in the following table:
Controller
Face 2-256, BUNA-N, 70 durometer
Radial 2-253, BUNA-N, 70 durometer
Back-up 8-253, BUNA-N, 90 durometer
4-1