User manual

Table Of Contents
Step
ì System
initialization
countdown
Step
í
Watchdog
activation
Step
î Flash
card sizing
Step
ï Setting
RTC
[ENTER] sets
RTC
System syncs
WDC
Step
ð
Profiling
history
MMP-4_04
McLane Moored Profiler operator interface.
The MMP operating system is initialized
and running.
Type <CTRL>-<C> within 30 seconds to
assert operator control and complete
system initialization.
30 seconds
29 seconds
28 seconds
27 seconds
26 seconds
Independent system watchdog successfully initialized.
Watchdog alarm IRQ has been activated.
Sizing flash card (~2 seconds / 100 Mbytes) . . . done.
521.347 Mbyte flash card installed
520.454 Mbyte currently free
File system can accommodate 4080 data files
Clock reads 01/01/1970 00:00:08
Change time & date (Yes/No) [N] ? y
Enter date as MM DD YY HH MM SS
Enter year 2001 as 1, 01, 101, or 2001
Enter correct time [01/01/1970 00:00:13] ? 03/21/07 09:45:00
Clock reads 03/21/2007 09:45:00
Change time & date (Yes/No) [N] ? n
Setting watchdog clock . . . done.
Profiling history:
Total motor hours: 59.31 hours
Total meters traveled: 125944 meters
Figure 7-2: Power Up Sequence
Re-Booting the System
The power-up sequence does not repeat unless the firmware is re-booted. Execute a
“cold” re-boot by disconnecting the power and then reconnecting it after 5 to 10 seconds. The
delay allows capacitors to fully discharge. Execute a “warm” re-boot, which will not reset the
RTC, by exiting the firmware to the TT8v2 monitor (TOM8) and then manually re-starting the
program.
7-3