SDS

Do not use water jet as an extinguisher, as this will spread the fire.
Unsuitable extinguishing
media
Contents under pressure. Pressurized container may rupture when exposed to heat or flame.
During fire, gases hazardous to health may be formed.
Specific hazards arising from
the chemical
Firefighters must use standard protective equipment including flame retardant coat, helmet with
face shield, gloves, rubber boots, and in enclosed spaces, SCBA.
Special protective equipment
and precautions for firefighters
Fire-fighting
equipment/instructions
In case of fire: Stop leak if safe to do so. Move containers from fire area if you can do so without
risk. Containers should be cooled with water to prevent vapor pressure build up.
Extremely flammable aerosol. Contents under pressure. Pressurized container may rupture when
exposed to heat or flame.
General fire hazards
6. Accidental release measures
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Keep out of
low areas. Many gases are heavier than air and will spread along ground and collect in low or
confined areas (sewers, basements, tanks). Wear appropriate protective equipment and clothing
during clean-up. Avoid breathing mist or vapor. Emergency personnel need self-contained
breathing equipment. Do not touch damaged containers or spilled material unless wearing
appropriate protective clothing. Ventilate closed spaces before entering them. Local authorities
should be advised if significant spillages cannot be contained. For personal protection, see section
8 of the SDS.
Personal precautions,
protective equipment and
emergency procedures
Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Keep
combustibles (wood, paper, oil, etc.) away from spilled material. This product is miscible in water.
Prevent product from entering drains. Stop the flow of material, if this is without risk. Wipe up with
absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
For waste disposal, see section 13 of the SDS.
Methods and materials for
containment and cleaning up
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all
environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into
drains, water courses or onto the ground.
Environmental precautions
7. Handling and storage
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Pressurized container: Do not pierce or burn, even after use. Do not use if spray
button is missing or defective. Do not spray on a naked flame or any other incandescent material.
Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill,
grind, or expose containers to heat, flame, sparks, or other sources of ignition. Use caution around
energized equipment. The metal container will conduct electricity if it contacts a live source. This
may result in injury to the user from electrical shock and/or flash fire. Avoid breathing mist or
vapor. Avoid contact with eyes, skin, and clothing. Avoid prolonged exposure. Pregnant or
breastfeeding women must not handle this product. Should be handled in closed systems, if
possible. Use only in well-ventilated areas. Wear appropriate personal protective equipment.
Wash hands thoroughly after handling. Avoid release to the environment. Observe good industrial
hygiene practices. For product usage instructions, please see the product label.
Precautions for safe handling
Level 3 Aerosol.
Pressurized container. Protect from sunlight and do not expose to temperatures exceeding
50°C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near an open flame,
heat or other sources of ignition. This material can accumulate static charge which may cause
spark and become an ignition source. Store in a well-ventilated place. Store away from
incompatible materials (see Section 10 of the SDS).
Conditions for safe storage,
including any incompatibilities
8. Exposure controls/personal protection
Occupational exposure limits
The following constituents are the only constituents of the product which have a PEL, TLV or other recommended exposure limit.
At this time, the other constituents have no known exposure limits.
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
ValueComponents
Form
Type
PEL 400 mg/m3naphtha (petroleum),
hydrotreated light (CAS
64742-49-0)
100 ppm
PEL 1800 mg/m3n-hexane (CAS 110-54-3)
500 ppm
PEL 5 mg/m3 Mist.petrolatum (CAS
8009-03-8)
3 / 10
Material name: Chain Lube
05012 Version #: 02 Revision date: 01-24-2017 Issue date: 02-25-2014