MSDS

Product Name: QD® Electronic Cleaner (aerosol)
Product Number (s): 05101, 05103, 05703
Page 2 of 7
Section 3: Composition/Information on Ingredients
COMPONENT CAS NUMBER % by Wt.
Hexane isomers
64742-49-0 / 107-83-5 /
96-14-0 / 75-83-2 / 79-29-8
65 – 75
n-Hexane 110-54-3 5.2
Ethanol 64-17-5 < 1
1,1-Difluoroethane (HFC-152a) 75-37-6 20 - 30
Section 4: First Aid Measures
Eye Contact: Immediately flush with plenty of water for 15 minutes. Call a physician if irritation persists.
Skin Contact: Remove contaminated clothing and wash affected area with soap and water. Call a physician if
irritation persists. Wash contaminated clothing prior to re-use.
Inhalation: Remove person to fresh air. Keep person calm. If not breathing, give artificial respiration. If
breathing is difficult give oxygen. Call a physician.
Ingestion: Do NOT induce vomiting. Contact a physician immediately.
Note to Physicians: Treat symptomatically. Gastric lavage using a cuffed endotracheal tube may be performed at your
discretion.
Section 5: Fire-Fighting Measures
Flammable Properties:
This product is extremely flammable in accordance with aerosol flammability definitions.
(See 16 CFR 1500.3(c)(6) ).
Flash Point: < 0°F / < -17°C (TCC) Upper Explosive Limit: 9.0
Autoignition Temperature: 489°F / 254°C Lower Explosive Limit: 1.7
Fire and Explosion Data:
Suitable Extinguishing Media: Class B fire extinguishers, dry chemical, foam or CO
2
Products of Combustion: Fumes, smoke and carbon monoxide
Explosion Hazards: Aerosol containers, when exposed to heat from fire, may build pressure and explode. Vapors
may accumulate in a confined space and create a flammable atmosphere.
Protection of Fire-Fighters:
Firefighters should wear self-contained, NIOSH-approved breathing apparatus for
protection against suffocation and possible toxic decomposition products. Proper eye and
skin protection should be provided. Use water spray to keep fire-exposed containers cool
and to knock down vapors which may result from product decomposition. Do not spray
water directly on fire; product will float and could be reignited on surface of water.
Section 6: Accidental Release Measures
Personal Precautions: Use personal protection recommended in Section 8.
Environmental Precautions: Take precautions to prevent contamination of ground and surface waters. Do not flush into
sewers or storm drains.