Certifications 2
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Occupational exposure limits
UK. EH40 Workplace Exposure Limits (WELs)
ValueComponents Type
STEL 27400 mg/m3Carbon dioxide (CAS
124-38-9)
15000 ppm
TWA 9150 mg/m3
5000 ppm
STEL 1250 mg/m3Propan-2-ol; Isopropyl
alcohol; Isopropanol (CAS
67-63-0)
500 ppm
TWA 999 mg/m3
400 ppm
EU. Indicative Exposure Limit Values in Directives 91/322/EEC, 2000/39/EC, 2006/15/EC, 2009/161/EU, 2017/164/EU
ValueComponents Type
TWA 9000 mg/m3Carbon dioxide (CAS
124-38-9)
5000 ppm
No biological exposure limits noted for the ingredient(s).
Biological limit values
Follow standard monitoring procedures.
Recommended monitoring
procedures
Derived no effect levels (DNELs)
General Population
NotesAssessment factorValueComponents
Hydrocarbons, C6-C7, n-alkanes,isoalkanes,cyclics,< 5% n-hexane (CAS EC921-024-6)
Long-term, Systemic, Dermal 699 mg/kg bw/day
Long-term, Systemic, Inhalation 608 mg/m3
Long-term, Systemic, Oral 699 mg/kg bw/day
Propan-2-ol; Isopropyl alcohol; Isopropanol (CAS 67-63-0)
Long-term, Systemic, Dermal 2 Repeated dose toxicity319 mg/kg bw/day
Long-term, Systemic, Inhalation 2 Repeated dose toxicity89 mg/m3
Long-term, Systemic, Oral 2 Repeated dose toxicity26 mg/kg bw/day
Workers
NotesAssessment factorValueComponents
Hydrocarbons, C6-C7, n-alkanes,isoalkanes,cyclics,< 5% n-hexane (CAS EC921-024-6)
Long-term, Systemic, Dermal 773 mg/kg bw/day
Long-term, Systemic, Inhalation 2035 mg/m3
Propan-2-ol; Isopropyl alcohol; Isopropanol (CAS 67-63-0)
Long-term, Systemic, Dermal 1888 mg/kg bw/day
Long-term, Systemic, Inhalation 1500 mg/m3
Predicted no effect concentrations (PNECs)
Components
Propan-2-ol; Isopropyl alcohol; Isopropanol (CAS 67-63-0)
Freshwater
Value
140.9 mg/l
Assessment factor
1
Notes
Secondary poisoning 160 mg/kg 30 Oral
Sediment (freshwater) 552 mg/kg
Soil 28 mg/kg
8.2. Exposure controls
Good general ventilation should be used. Ventilation rates should be matched to conditions. If
applicable, use process enclosures, local exhaust ventilation, or other engineering controls to
maintain airborne levels below recommended exposure limits. If exposure limits have not been
established, maintain airborne levels to an acceptable level. Provide eyewash station and safety
shower.
Appropriate engineering
controls
SDS UK
Material name: Contact Cleaner FPS - Manufacturers
BDS000082AE Version #: 01 Issue date: 20-April-2021