MSDS

Product Name: HydroForce® Glass Cleaner
Product Number (s): 14411, 14413, 14427, 74411
Page 2 of 7
Section 3: Composition/Information on Ingredients
COMPONENT CAS NUMBER % by Wt.
Water 7732-18-5 90 – 99
2-Butoxyethanol 111-76-2 2.5
Ammonium hydroxide solution 1336-21-6 < 1
Isopropyl alcohol 67-63-0 1 – 2
Section 4: First Aid Measures
Eye Contact: Immediately flush with plenty of water for 15 minutes. Call a physician if irritation persists.
Skin Contact: Remove contaminated clothing and wash affected area with soap and water. Call a physician if
irritation persists. Wash contaminated clothing prior to re-use.
Inhalation: Remove person to fresh air. Keep person calm. If not breathing, give artificial respiration. If
breathing is difficult give oxygen. Call a physician.
Ingestion: Do not induce vomiting. Call a physician.
Note to Physicians: This product contains 2-Butoxyethanol which, if ingested in significant quantities, may result in red
blood cell hemolysis.
Section 5: Fire-Fighting Measures
Flammable Properties:
As defined by OSHA, this product is nonflammable.
Flash Point: None Upper Explosive Limit: None
Autoignition Temperature: None Lower Explosive Limit: None
Fire and Explosion Data:
Suitable Extinguishing Media: Use extinguishing agents appropriate for surrounding fire.
Products of Combustion: None
Explosion Hazards: Containers, when exposed to heat from fire, may build pressure and rupture.
Protection of Fire-Fighters:
Firefighters should wear self-contained, NIOSH-approved breathing apparatus for
protection against suffocation and possible toxic decomposition products. Proper eye and
skin protection should be provided. Use water spray to keep fire-exposed containers cool
and to knock down vapors which may result from product decomposition.
Section 6: Accidental Release Measures
Personal Precautions: Use personal protection recommended in Section 8.
Environmental Precautions: Take precautions to prevent contamination of ground and surface waters. Do not flush into
sewers or storm drains.
Methods for Containment & Clean-up: Dike area to contain spill. Ventilate the area with fresh air. If in confined space
or limited air circulation area, clean-up workers should wear appropriate
respiratory protection. Recover or absorb spilled material using an absorbent