MSDS

Product Name:
Upside Down Marking Paint:
Product Number (s):
18210
Red/Orange Fluorescent
Page 3 of 6
Section 6: Accidental Release Measures
Personal Precautions:
Use personal protection recommended in Section 8.
Environmental Precautions:
Take precautions to prevent contamination of ground and surface waters. Do not flush
into sewers or storm drains.
Methods for Containment & Clean-up:
Remove all sources of ignition. Dike area to contain spill. Ventilate the area
with fresh air. If in confined space or limited air circulation area, clean-up
workers should wear appropriate respiratory protection. Recover or absorb
spilled material using an absorbent designed for chemical spills. Place used
absorbents into proper waste containers.
Section 7: Handling and Storage
Handling Procedures:
Do not use on energized equipment or near sources of ignition. Do not inhale vapors. Use
local ventilation.
Storage Procedures:
Store in a cool dry area out of direct sunlight. Aerosol cans must be maintained below 120 F
to prevent cans from rupturing.
Aerosol Storage Level:
II
Section 8: Exposure Controls/Personal Protection
Exposure Guidelines:
OSHA ACGIH
OTHER
COMPONENT TWA STEL TWA STEL TWA SOURCE UNIT
Toluene 200 300 (c) 20 NE NE ppm
Xylene 100 150 (v) 100 150 NE ppm
Ethylbenzene 100 125 (v) 100 125 NE ppm
Calcium carbonate 15 NE 10 NE NE mg/m
3
VM&P naphtha 300 (v) NE 300 NE NE ppm
Mineral spirits 500 NE 100 NE NE ppm
Isobutane 1000 NE 1000 NE NE ppm
Propane 1000 NE 1000 NE NE ppm
N.E. – Not Established (c) – ceiling (s) – skin (v) – vacated
Engineering Controls:
Area should have ventilation to provide fresh air. Local exhaust ventilation is generally
preferred because it can control the emissions of the contaminant at the source, preventing
dispersion into the general work area. Use mechanical means if necessary to maintain
vapor levels below the exposure guidelines. If working in a confined space, follow
applicable OSHA regulations.
Respiratory Protection:
None required for normal work where adequate ventilation is provided. If engineering
controls are not feasible or if exposure exceeds the applicable exposure limits, use a
NIOSH-approved cartridge respirator with organic vapor / paint cartridge. Use a self-
contained breathing apparatus in confined spaces and for emergencies.