Certifications 2

Short-term, Local, Inhalation respiratory tract irritation1900 mg/m3
Propan-2-ol; Isopropyl alcohol; Isopropanol (CAS 67-63-0)
Long-term, Systemic, Dermal 1888 mg/kg bw/day
Long-term, Systemic, Inhalation 1500 mg/m3
Reaction mass of dimethyl adipate and dimethyl glu (CAS EC906-170-0)
Long-term, Local, Inhalation 8.3 mg/m3
Predicted no effect concentrations (PNECs)
Components
1-METHOXY-2-PROPANOL; MONOPROPYLENE GLYCOL METHYL ETHER (CAS 107-98-2)
Freshwater
Value
10 mg/l
Assessment factor
100
Notes
Intermittent releases 100 mg/l 10
Marine water 1 mg/l 1000
Sediment (freshwater) 52.3 mg/kg
Sediment (marine water) 5.2 mg/kg
Soil 4.59 mg/kg
STP 100 mg/l 10
ethanol; ethyl alcohol (CAS 64-17-5)
Freshwater 0.96 mg/l 10
Intermittent releases 2.75 mg/l 100
Marine water 0.79 mg/l 100
Secondary poisoning 0.38 g/kg 90 Oral
Sediment (freshwater) 3.6 mg/kg
Sediment (marine water) 2.9 mg/kg
Soil 0.63 mg/kg 1000
STP 580 mg/l 10
Propan-2-ol; Isopropyl alcohol; Isopropanol (CAS 67-63-0)
Freshwater 140.9 mg/l 1
Marine water 140.9 mg/l 1
Secondary poisoning 160 mg/kg 30 Oral
Sediment (freshwater) 552 mg/kg
Sediment (marine water) 552 mg/kg
Soil 28 mg/kg
Reaction mass of dimethyl adipate and dimethyl glu (CAS EC906-170-0)
Freshwater 0.018 mg/l
Intermittent releases 0.18 mg/l
Marine water 0.0018 mg/l
Sediment (freshwater) 0.16 mg/kg
STP 10 mg/l
Exposure guidelines
UK EH40 WEL: Skin designation
1-METHOXY-2-PROPANOL; MONOPROPYLENE
GLYCOL METHYL ETHER (CAS 107-98-2)
Can be absorbed through the skin.
8.2. Exposure controls
Good general ventilation should be used. Ventilation rates should be matched to conditions. If
applicable, use process enclosures, local exhaust ventilation, or other engineering controls to
maintain airborne levels below recommended exposure limits. If exposure limits have not been
established, maintain airborne levels to an acceptable level. Provide eyewash station.
Appropriate engineering
controls
Individual protection measures, such as personal protective equipment
Use personal protective equipment as required. Personal protection equipment should be chosen
according to the CEN standards and in discussion with the supplier of the personal protective
equipment.
General information
Use eye protection conforming to EN 166.
Eye/face protection
Skin protection
When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough
time of the glove should be longer than the total duration of product use. If work lasts longer than
the breakthrough time, gloves should be changed part-way through. For prolonged or repeated
skin contact use suitable protective gloves. Suitable gloves can be recommended by the glove
supplier. Full contact: Glove material: butylrubber. Use gloves with breakthrough time of 480
minutes. Minimum glove thickness 0.38 mm.
- Hand protection
Not available.
- Other
Chemical respirator with organic vapour cartridge and full facepiece. (Filter type A)
Respiratory protection
Wear appropriate thermal protective clothing, when necessary.
Thermal hazards
SDS UK
Material name: GRAFFITI REMOVER AE - Manufacturers
BDS000443AE Version #: 01 Issue date: 08-October-2020
5 / 10