Certifications 2
Use standard firefighting procedures and consider the hazards of other involved materials. In the
event of fire and/or explosion do not breathe fumes.
Specific methods
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Wear
appropriate protective equipment and clothing during clean-up. Do not touch damaged containers
or spilled material unless wearing appropriate protective clothing. Ventilate closed spaces before
entering them. Local authorities should be advised if significant spillages cannot be contained. For
personal protection, see section 8 of the SDS.
For non-emergency
personnel
Keep unnecessary personnel away. Use personal protection recommended in Section 8 of the
SDS.
For emergency responders
Avoid discharge into drains, water courses or onto the ground.
6.2. Environmental precautions
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the leak is
irreparable. Use water spray to reduce vapours or divert vapour cloud drift. Eliminate all ignition
sources (no smoking, flares, sparks, or flames in immediate area). Keep combustibles (wood,
paper, oil etc) away from spilled material. The product is immiscible with water and will spread on
the water surface. Absorb in vermiculite, dry sand or earth and place into containers. Following
product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
6.3. Methods and material for
containment and cleaning up
For personal protection, see section 8 of the SDS. For waste disposal, see section 13 of the SDS.
6.4. Reference to other
sections
SECTION 7: Handling and storage
Pressurised container: Do not pierce or burn, even after use. Do not use if spray button is missing
or defective. Do not spray on a naked flame or any other incandescent material Do not smoke
while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or
expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when
handling the product must be grounded. Do not re-use empty containers. Avoid prolonged
exposure. Use only in well-ventilated areas. Wear appropriate personal protective equipment.
Observe good industrial hygiene practices.
7.1. Precautions for safe
handling
Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50°C.
Do not puncture, incinerate or crush. Do not handle or store near an open flame, heat or other
sources of ignition. This material can accumulate static charge which may cause spark and
become an ignition source. Store away from incompatible materials (see Section 10 of the SDS).
7.2. Conditions for safe
storage, including any
incompatibilities
Not available.
7.3. Specific end use(s)
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Occupational exposure limits
UK. EH40 Workplace Exposure Limits (WELs)
ValueComponents Type
STEL 27400 mg/m3Carbon dioxide (CAS
124-38-9)
15000 ppm
TWA 9150 mg/m3
5000 ppm
TWA 308 mg/m3Dipropylene glycol
monomethyl ether (CAS
34590-94-8)
50 ppm
EU. Indicative Exposure Limit Values in Directives 91/322/EEC, 2000/39/EC, 2006/15/EC, 2009/161/EU, 2017/164/EU
ValueComponents Type
TWA 9000 mg/m3Carbon dioxide (CAS
124-38-9)
5000 ppm
TWA 308 mg/m3Dipropylene glycol
monomethyl ether (CAS
34590-94-8)
50 ppm
No biological exposure limits noted for the ingredient(s).
Biological limit values
SDS UK
Material name: LECTRA CLEAN II
BDS000279AE Version #: 01 Issue date: 23-September-2020