Certifications 2
Safety Data Sheet
Regulation EC No 1907/2006 Art.31
Productname :
CONTACT CLEANER
Creationdate :
29.06.17 Version : 3.1
Ref.Nr.:
BDS000082_3_20170629 (EN)
Replaces:
BDS000082_20160310
CRC Industries Europe bvba
Touwslagerstraat 1, 9240 Zele – Belgium
Tel (+32) (0) 52 / 45 60 11 – Fax (+32) (0) 52 / 45 00 34 – www.crcind.com
5 / 10
7.1. Precautions for safe handling
Keep away from heat and sources of ignition
Take precautionary measures against static discharges
Equipment should be earthed
Use explosion-proof electrical/ventilating/lighting/.../equipment.
Use only non-sparking tools.
Do not breathe aerosols or vapours.
Ensure adequate ventilation
Avoid contact with skin and eyes.
Wash thoroughly after use
Wear protective gloves/protective clothing/eye protection/face protection.
Eyewash bottles should be available
7.2. Conditions for safe storage, including any incompatibilities
Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep out of reach of children.
7.3. Specific end use(s)
Cleaners - Precision
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Exposure limits :
Hazardous ingredient
CAS-nr.
method
EU established exposure limits:
carbon dioxide
124-38-9
TWA
9000 mg/m3
STEL
1800 mg/m3
propan-2-ol; isopropyl alcohol ;isopropanol
67-63-0
TWA
400 ppm
STEL
500 ppm
National established exposure limits, United Kingdom
carbon dioxide
124-38-9
TWA
5000 ppm
STEL
15000 ppm
propan-2-ol; isopropyl alcohol ;isopropanol
67-63-0
TWA
400 ppm
STEL
500 ppm
8.2. Exposure controls
Control procedures :
Ensure adequate ventilation
Keep away from heat and sources of ignition
Take precautionary measures against static discharges
Personal protection :
Take precautions to avoid contact with skin and eyes when handling the
product.