User's Manual

Table Of Contents
ADDICT v3.0.1 User Manual DALI Functionality
©2017 All rights reserved - 37 -
After the bus ID and address have been selected, the ADDICT
®
will ask for confirmation for
capturing. If a new slot is required and there isn’t a free slot available, capturing will not
proceed.
Selectable values:
Bus ID (0 99) the bus ID to associate with the stored settings
Address (0 63) the address of the device to store the common settings for. Press
enter to proceed to confirmation
Confirmation (YES, NO) Press enter to confirm Capture 1 by 1, YES to start capturing,
NO to cancel
View Stored
View Stored allows a bus ID to be selected and then addresses associated with that bus ID can be
viewed (within the data stored in the ADDICT
®
).
The following examples show that there are stored settings for address 2 with bus ID 15, and
address 50 with bus ID 50.
Note: only one address is displayed at a time, and other addresses for the selected bus ID can be
displayed by navigating down to the address.
A bus ID of “ALL” can also be selected, which shows how many slots out of the total of 250 are
currently being used:
Selectable values:
Bus ID (0 99, ALL) the bus ID’s used when storing settings (only used bus ID’s can be
selected)
Address (0 63) one of the addresses associated with the selected bus ID