Specifications

Table Of Contents
1 - 4
1.2 Outline of control
1.2.1 Real mode control for SV13 transfer assembly and SV22 automatic machine
(a) A system containing a servomotor is directly controlled with the servo program.
(b) The positioning parameters must be set, and the servo program and positioning
sequence program must be created.
(c) The procedures for positioning control are indicated below.
1) Start up of the motion SFC program is requested with the sequence
program's SFCS command
2) Positioning control is carried out with the designated motion SFC program
3) The servomotor is controlled
Servo amplifier
Servomotor
Sequence program
Motion SFC program
Transfer
[K10: Real
1 INC-2
Axis 1, 10000 PLS
Axis 2, 20000 PLS
Composite speed 30000 PLS/sec
[G100]
M2049//Accept servo ON?
END
K0
.........
Motion SFC
program start
request
command
Start program No. designation
1)
3)
2)
Q-PLC CPU
Q motion CPU
* The motion SFC program can also be started
automatically with parameter settings.
SP.SFCS
Servo program
Parameters for positioning
SYSTEM SETTING
FIXED PARA
SERVO PARA
P.B. DATA
ZERO P. DATA
JOG DATA
LMT. SW. DATA
.........