CREDA SPA300C ELECTRIC SHOWER Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration
CONTENTS Section Page Section Page Introduction . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Information . . . . . . . . . . 2 What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . 9 How to install your SPA300C Shower . . . . . 3 Cold Water Inlet Pipe Configuration. . . . . . . Assembly of Accessories . . . . . . . . . . . . . . 5 7 What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . .
HOW TO INSTALL YOUR SPA300C SHOWER WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY QUALIFIED PERSON. WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE SUBJECTED TO FREEZING CONDITIONS We recommend that the installation is done in the following sequence. a. Fixing the shower to the wall b. Plumbing c. Electrical connections a. FIXING THE SHOWER TO THE WALL 1. Position the riser rail at a convenient height for majority of users as detailed in Diagram 1 and mark its position. 2.
8. Your shower is provided with 3 fixing positions in the backplate (see Diagram 6). The top-fixing hole is a “key-hole” slot, and should be marked and drilled first. Tighten top screw with head protruding about 10mm from the wall and hook the backplate over the screw head. This allows for correct and accurate alignment of your shower before marking and fixing the bottom positions.
COLD WATER INLET PIPE CONFIGURATION Please note that standard compression fittings are shown. Push-Fit connections or a combination of the two are also suitable. To aid installation, you may find it convenient to move the flexible pressure relief valve outlet assembly by removing the two securing screws. If you do, please ensure that they are fully tightened on re-assembly (see Diagram 2b).
c) ELECTRICAL WARNING: THIS SHOWER MUST BE EARTHED. The electrical installation must be in accordance with the current BS.7671 (IEE Wiring Regulations) and “Part P” of the Building Regulations and/or local regulations. 1. The shower unit is designed for a single phase AC electrical supply. Please check the rating plate on the unit to see what details apply to your shower. AS A GUIDE ONLY (* Only applies if external earth impedance is less than 0.35 Ohms) Rating 8.5 / 7.8kW 240 / 230V 9.5 / 8.
. Fit the shower hose, and operate the shower first without the handset to flush out particles, fit the handset and then operate the shower as on page 8 or 12 and check: • Water gets to a satisfactory temperature and water flow can be adjusted by control knob “E”. • Knob “E” has been correctly engaged by ensuring that the knob turns approximately one full turn. • Power selection operates in all 3 button settings, giving a change in water temperature.
HOW TO USE YOUR SPA300C SHOWER (DETAILED) 1. Ensure the electricity and water are turned on to the unit. 2. Your shower can be turned on by pressing either Button “A”, Button “B” or Button “C” (see Diagram 5). Button “A” (III) - Starts shower on “High” power. Button “B” (II) - Starts shower on “Medium” power. Button “C” (I) - Starts shower on “Cold”. Once pressed, a light will illuminate above the button confirming that power selection has been made.
WHAT TO DO IF THINGS GO WRONG (1) SELF HELP If the shower is not working satisfactorily, make the following checks before calling out the installer. Any one of these adjustments could restore the performance. The shower cycles from HOT to COLD Water too HOT Water too COLD Spray pattern poor Water takes longer to heat up Water goes cold while using shower Broken parts Water continues to flow when button “D” pressed to stop Temperature is set too hot causing the thermal cut-out (safety device) to operate.
HOW YOUR SPA300C SHOWER WORKS 1. Water is heated instantaneously as it flows over the heating elements in the copper cylinder (Diagram 6). 2. The heaters are only switched on when sufficient water is flowing. This is done automatically with a switch which works on water pressure and is indicated by the LED indicator illuminating. 3. The water is turned on and off by the solenoid valve and Control PCB built into the shower. This is switched on when button “A”, “B” or “C” is pressed. 4.
CREDA AFTER SALES SERVICE We offer a technical advisory service on the telephone to installers and other customers with problems in the field. RING 0870 9000 430 (UK ONLY) Remember to quote the exact type of shower, as written on the shower front and on is leaflet. The model and serial number are located on the bottom face of the shower. Make a note of those numbers here, and be sure to quote them if you call for advice.
HOW TO USE YOUR SPA300C SHOWER (SUMMARY) 1. Ensure the electricity and water are turned on to the unit. 2. Your shower can be turned on by pressing either Button “A”, Button “B” or Button “C” Button “A” (III) - Starts shower on “High” power. Button “B” (II) - Starts shower on “Medium” power. Button “C” (I) - Starts shower on “Cold”. Press Button “A”, “B” or “C”. Water will flow and the LED indicator above your choice will illuminate.