Datasheet

Copyright © 2011-2014 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
, the Cree logo and XLamp
®
are registered
trademarks of Cree, Inc.
3
xlamp
®
xB-D leDs
FLUX CHARACTERISTICS - WHITE (T
J
= 85 °C)
The following table provides several base order codes for XLamp XB-D LEDs. It is important to note that the base order
codes listed here are a subset of the total available order codes for the product family. For more order codes, as well
as a complete description of the order-code nomenclature, please consult the XLamp XB-D LED Binning and Labeling
document.
Color
CCT Range
Base Order Codes
Min. Luminous Flux
@ 350 mA
Calculated Minimum
Luminous Flux (lm)**
Order Code
Min. Max. Group
Flux (lm)
@ 85 °C
Flux (lm)
@ 25 °C*
700 mA 1000 mA
Cool White 5000 K 8300 K
R3 122 139 210 271 XBDAWT-00-0000-000000F51
R2 114 130 196 253 XBDAWT-00-0000-000000E51
70 CRI Minimum
Cool White
5000 K 8300 K
R3 122 139 210 271 XBDAWT-00-0000-00000BF51
R2 114 130 196 253 XBDAWT-00-0000-00000BE51
Neutral White 3700 K 5000 K
R2 114 130 196 253 XBDAWT-00-0000-00000LEE4
Q5 107 122 184 237 XBDAWT-00-0000-00000LDE4
Q4 100 114 172 222 XBDAWT-00-0000-00000LCE4
80 CRI Minimum
White
2600 K 6200 K
Q4 100 114 172 222 XBDAWT-00-0000-00000HCE7
Q3 93.9 107 162 208 XBDAWT-00-0000-00000HBE7
Q2 87.4 100 150 194 XBDAWT-00-0000-00000HAE7
Warm White 2600 K 3700 K
Q4 100 114 172 222 XBDAWT-00-0000-00000LCE7
Q3 93.9 107 162 208 XBDAWT-00-0000-00000LBE7
Q2 87.4 100 150 194 XBDAWT-00-0000-00000LAE7
Notes:
Cree maintains a tolerance of ±7% on ux and power measurements, ±0.005 on chromaticity (CCx, CCy)
measurements and ±2 on CRI measurements. See the Measurements section (page 14).
Typical CRI for Neutral White, 3700 K - 5000K CCT is 75.
Typical CRI for Warm White, 2600 K - 3700 K CCT is 80.
Minimum CRI for 70 CRI Minimum Cool White is 70.
Minimum CRI for 80 CRI Minimum White is 80.
* Flux values @ 25 °C are calculated and are for reference only.
** Calculated ux values at 700 mA and 1000 mA are for 85 °C and are for reference only.
3