Operating instructions
Ovens
FL-2340-D
Rev. 3 (2/15) Page 9 of 13
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE
IF UNIT GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
1. Cord is unplugged from wall outlet.
2. Circuit breaker/fuse to wall outlet is blown.
3. Switch(es) are turned off.
4. Thermostat(s) are turned off, or are set too low.
If hot unit is NOT working, rst check the following causes:
WARNING
IF THE OVEN TURNS ON:
PROBLEM POSSIBLE CAUSE SOLUTION
Oven does not heat, or doesn’t heat
properly
1. Sensor
2. Heater relay
3. Loose connection
4. Oven control
5. High Limit
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
Heater will not shut off
1. Control defective
2. Heater relay
1. Replace
2. Replace
Vent fans do not shut off
1. Vent fan switch defective
2. Control compartment is still hot.
1. Replace
2. Wait until it cools
Check “Heater will not shut off”
Vent fans do not operate (See Note)
1. Vent fan switch defective
2. Vent fan defective
1. Replace
2. Replace
Control will not switch from “COOK” to
“HOLD” (timed mode)
1. Oven is in “PROBE” mode (DX oven).
2. Oven control defective
1. Cancel recipe and switch to “TIMED” mode
2. Replace
Control will not switch from “COOK” to
“HOLD” (probe mode in DX ovens only)
1. Oven is in the “TIMED” mode
2. Probe not plugged in
3. Probe defective
4. Oven control defective
1. Cancel recipe and switch to “PROBE” mode
2. Plug in probe
3. Replace
4. Replace
Control will not switch to “COOK”
(probe mode in DX ovens only)
1. Oven in “TIMED” mode
2. Probe temperature setting lower
than probe temperature
3. Probe not plugged in
4. Oven control defective
1. Switch to “PROBE” mode
2. Set probe temperature to desired temperature
3. Plug in probe
4. Replace
ERROR CODES:
CODE DISPLAYED CAUSE SOLUTION
no p No meat probe Plug in probe
Err0 Temp probe bad Replace
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement
of electrical components must be done by a qualied electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers.
Instructions for replacing parts are included in replacement parts list.