Installation and Operating Manual

User Manual
040003A010 Rev A Page 15 of 25
COMMAND
RETURNED ANSWER
NOTES
"PM?\r"
"PM=***W\r"
Example:
“PM=250W\r”
“PM=EX\r”
Return power level that is saved in
nonvolatile memory. If the external control
of output power level is enabled, the
amplifier returns “EX” value.
"CF?\r"
“CF=1\r”
Return CHECK FAN alarm status.
(0 - alarm; 1 - normal operation)
"F1?\r"
“F1=*****RPM\r”
Example:
“F1=03450RPM\r”
Return fan 1 speed.
"F2?\r"
“F2=*****RPM\r”
Example:
“F2=03500RPM\r”
Return fan 2 speed.
"FT?\r"
“FT=*****RPM\r”
Example:
“FT=03500RPM\r”
Return CHECK FAN alarm speed
threshold.
“PF?\r”
“PF=*\r”
Example:
“PF=1\r”
Return PA FAULT alarm sate.
(0 - alarm; 1 - normal operation)
“LO?\r”
“LO=*\r”
Example:
“LO=1\r”
Return LOW OUTPUT alarm state.
(0 - alarm; 1 - normal operation)
“HT?\r”
“HT=*\r”
Example:
“HT=1\r”
Return HI TEMP alarm state.
(0 - alarm; 1 - normal operation)
“HI?\r”
“HI=*\r”
Example:
“HI=1\r”
Return HI INPUT alarm state.
(0 - alarm; 1 - normal operation)
“HR?\r”
“HR=*\r”
Example:
“HR=1\r”
Return HI VSWR alarm state.
(0 - alarm; 1 - normal operation)