PWR ON
EXCITER DRIVE
/ RF DRIVE
OUTPUT POWER 
STATUS
PA FAULT
CHECK FAN
HI TEMP
HI VSWR
HI INPUT
LOW OUTPUT
OTHER 
SYMPTOMS
POSSIBLE 
CAUSE 
SUGGESTED 
ACTIONS 
Amplifier failure. 
Verify exciter signal 
frequency and level. 
Obtain RMA to have 
amplifier checked at 
factory. 
ON 
ON 
Full 
power 
High 
ON 
High power input 
signal level has 
been detected. 
Turn off input drive. 
Verify exciter signal 
level. 
OFF 
OFF 
No 
power 
High 
Fuse failure 
Disconnect AC cord. 
Check fuse and 
replace if necessary. 
No AC power is 
applied to amplifier. 
Verify AC power 
source. 
Power Supply 
failure 
Obtain RMA to have 
amplifier checked at 
factory. 
OFF 
OFF 
No 
power 
High 
Fans 
operate 
Amplifier failure 
Obtain RMA to have 
amplifier checked at 
factory. 
ON 
ON 
No 
power  
High 
ON 
Ambient 
temperature is 
above 60C. 
Turn off input drive. 
Allow amplifier to cool 
down. 
Verify cabinet 
ventilation and room 
air temperature. 
Air circulation is 
blocked. 
Turn off input drive. 
Allow amplifier to cool. 
Disconnect AC cord. 
Clean up air vents. 
Remove any obstacles 
from air inlet and 
outlet. 