Installation and Operating Manual
User Manual 
040003A010 Rev A      Page 24 of 25   
4.  In instances where the effective antenna gain (antenna gain – feedline loss) differs from 
the example above, the MPE radius must be calculated by the licensee. Table 4-1 presents 
the results of calculations of the MPE radius for a 250 Watt 406 MHz transmitter having 
various effective antenna gain values. 
Table 6-1 Calculations of the MPE Radius for a 250 Watt 406 MHz Transmitter 
WARNING: Failure to observe the minimum safe distance radius may result in exposure to RF 
radiated energy in excess of the FCC Maximum Permissible Exposure (MPE) limit. 
The licensee is responsible for the safe operation of the base site and must ensure 
that the Maximum Permissible Exposure limits are observed at all times.  
Effective Antenna Gain 
(dBi) 
Minimum Safe Distance 
(meters) 
Minimum Safe Distance 
(feet) 
3.0 
3.83 
12.6 
4.0 
4.30 
14.1 
5.0 
4.82 
15.8 
6.0 
5.41 
17.7 
7.0 
6.07 
19.9 
8.0 
6.81 
22.3 
9.0 
7.64 
25.1 
10.0 
8.57 
28.1 