Cressi Copertina2 28-09-2005 14:25 Pagina 1 Manuale d’istruzioni Notice d’instructions Gebrauchsanweisung Manual de instrucciones User’s Manual
7-09-2005 16:17 Pagina 127 User’s Manual ENGLISH ARCHIMEDE 1
27-09-2005 16:17 Pagina 129 TABLE OF CONTENTS 3.6. - PO2 Alarms ( ) . . . . . . . . . . . . . . . . . . . . . . . . . .pag. 145 4. - ON SURFACE AFTER DIVE . . . . . . . . . . . . . . . . .pag. 146 4.1. - Data Management . . . . . . . . . . . . . . . . . . . . . . . . . .pag. 147 4.1.1. - Surface Interval Time ( SURF.T, DESAT, ) . . . . . . . .pag. 147 4.1.2. - Dive Logbook ( ) . . . . . . . . . . . . . . . . . . . . . . . .pag. 147 4.1.3. - Dive History ( ) . . . . . . . . . . . . . . . . . . . . . .
ARCHIMEDE 1 27-09-2005 16:17 Pagina 130 1. - INTRODUCTION. 1.2. - SAFETY RULES. Congratulations on your purchase of an Archimede Cressisub dive computer. It is a sophisticated and comprehensive device designed to offer you utmost safety, efficiency, and reliability over time. 1.2.1. - Definition of Danger, Important, and Note. This manual highlights certain points of particular importance. Before reading these instructions, it is essential to properly understand the following definitions: 1.1.
27-09-2005 16:17 Pagina 131 fatigue, and dehydration. All these conditions and all those that can jeopardize your safety should be avoided. IMPORTANT: The use of this dive computer is strictly personal. The information it provides exclusively refers to the diver who has used it during the single or repetitive dives. IMPORTANT: this device should be used by certified divers only. No dive computer can actually replace proper training. Do remember that dive safety can be ensured by proper training only.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 132 Cressi-sub reminds you that sport dives must always be kept within the safety limits and at maximum 131 ft depth, which is the standard maximum depth for recreational diving: if you exceed these limits, you significantly increase your DCS risk. It is extremely important that you carefully read and understand this User’s Manual. Otherwise,decompression sickness or death may occur.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 133 Photo Ghisotti ENGLISH 2) Before dive
ARCHIMEDE 1 27-09-2005 16:17 Pagina 134 2.1. - UFDS Display and Controls. By repeatedly pressing the M (Mode) button, you can scroll through all Archimede’s programs, and clearly display them on the alphanumeric UFDS display. Some of the programs also have sub-menus that can be accessed with the A and B ( , , i ) buttons. With these buttons you can also change surface data settings and with the B ( ) button, you turn on the display light. 2.2. - On Surface, prior to Dive.
27-09-2005 16:17 Pagina 135 than the balanced condition he/she had at the original altitude. This extra nitrogen is gradually eliminated and the balance resumed after a couple of days. where : • PO2 is the maximum partial oxygen pressure. It can be set by the diver with values from 1.0 bar to 1.6 bar (both values included), with changes of 0.1 bar, whenever you press the B ( ).
ARCHIMEDE 1 27-09-2005 16:17 Pagina 136 Once you get to the Max Depth (fig. 4 a) screen, press the A ( i ) button and select either the ON or OFF function with the B ( ) button. If you select ON, you can set the maximum depth in advance from 0 ft to 325ft, using the A and B ( i and ) buttons. IMPORTANT: Turn on the safety factor whenever you realize that there are factors likely to increase your DCS risk. You will thus perform a more conservative dive. • Max Depth is the maximum depth alarm (fig.
27-09-2005 16:17 Pagina 137 2.3.4. - Unit of Measure Setting. Related topics: The Archimede Cressi-sub dive computer can calculate and give you the values in metric units (depth values expressed in meters and temperature expressed in °C), or in Imperial units (depth in feet and temperature in °F). • 3.1.1. - No Decompression Dive. • 4.1.1. - Surface Interval Time. If you want to change the unit of measure, press the M (Mode) button to access the ( ) screen (fig. 3).
ARCHIMEDE 1 27-09-2005 16:17 Pagina 138 3) During dive Photo Olmi
27-09-2005 16:17 Pagina 139 3.1. - DIVE WITH AIR. The UFDS display shows ( ). Related topics: The “Dive” program is automatically turned on by the Archimede dive computer at a depth of more than 5ft. During a no-decompression dive, the following information is displayed (fig. 9): 2 elapsed dive time, indicated with “DIVE T” • • • • 3 maximum depth expressed in meters (m) or in feet (ft) 3.1.1. - No Decompression Dive.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 140 DANGER: when you ascend too fast, the risk of accident increases! Cressi-sub recommends to have a 3-5 min. safety stop at 10ft-20ft, at the end of every dive, which will be assisted by your dive computer (see chapter 3.1.3.) Related topics: • 2.3.4. - Unit of Measure Setting. • 3.1.2. - Ascent Rate. 3.2. - Decompression Warning Alarm.
27-09-2005 16:17 Pagina 141 2 Depth of the first decompression stop, indicated in meters (m) or in feet (ft); it may range from 100ft to a minimum of 10ft, with decreases of 10ft at a time; case, stop time will be automatically adjusted by your Archimede dive computer.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 142 Related topics: • • • • • • 3.1. 3.3. 3.2.1. 3.5. 3.6. 4.1.2. - Related topics: DIVE WITH AIR. DIVE WITH NITROX. Decompression Dive. CNS Toxicity Display. PO2 Alarms. Dive Logbook. • • • • • 2.3.1. 2.5. 3.4. 3.5. 3.6. - Dive Parameter Setting Quick Display of Set Data. Nitrox Parameter Setting. CNS Toxicity Display. PO2 Alarms. 3.3. - DIVE WITH NITROX . 3.4. - Nitrox Parameter Setting. 3.3.1. - Prior to a Nitrox Dive. 3.4.1.
27-09-2005 16:17 Pagina 143 NOTE: by keeping the B ( ) button pressed, the dive computer will automatically stop on the standard Nitrox 1 percentage (EAN32), or on the ( ) setting. where PO2 stands for maximum partial Oxygen pressure which, as we have already seen, can be set by the diver to values ranging from 1.0 bar to 1.6 bar, with 0.1 bar increases/decreases at a time by pressing the B ( ) button.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 144 Within the first 10 minutes of surface interval, you cannot enter the ( ) screen to change the parameter settings, hence you cannot change the previously set oxygen fraction 3.5. - CNS Toxicity Display The Archimede Cressi Sub dive computer gives you a graphic display of the degree of Central Nervous System oxygen poisoning, which is linked to Partial Oxygen Pressure as well as to the diver’s exposure time to high Partial Oxygen Pressure (PO2).
ARCHIMEDE 1 27-09-2005 16:17 Pagina 145 Related topics: • • • • • • 3.1. 3.3. 3.4.1. 3.4.2. 3.6. 4.1.2. - 2 DIVE WITH AIR. DIVE WITH NITROX. Partial Pressure Setting (PO2) page. Oxygen Fraction Setting FO2. PO2 Alarms. Dive Logbook. A second alarm will sound in any case whenever a depth corresponding to a PO2 value of 1.6 bar is reached. The display will blink for 15 seconds until you ascend above the depth limit again. Both alarms will be recorded in the Logbook. Related topics: • • • • 3.6.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 146 4) On surface after dive Photo Ghisotti
27-09-2005 16:17 Pagina 147 4.1. - Data Management. and dive time calculation will be resumed from where they have last stopped. This chapter deals with “surface” functions, namely data management after a dive. By repeatedly pressing the M (Mode) button , you can enter the following functions: ( ) - Dive Logbook (chapter 4.1.2.); ( ) - Dive History (chapter 4.1.3.); ( )- Dive Profile (chapter 4.1.4.); Data transfer to PC with interface (optional) (chapter 4.1.5.).
ARCHIMEDE 1 27-09-2005 16:17 Pagina 148 ( On the main display screen (fig. 24), UFDS display indicates that the ( ) function is on, displaying the following information: 1 PO2 )(PO2 alarm); ( SLOW ) (maximum ascent rate alarm) etc. In order to display the second Logbook screen, simply press the button corresponding to the ( ) icon on the UFDS display.
27-09-2005 16:17 Pagina 149 2 Water temperature recorded during the dive at maximum depth and expressed in °C or in °F. 3 total number of previous dives indicated with the “DIVE” icon. 3 Surface interval time expressed in hours and minutes; The ( ) function can store information up to 599 dives. After this total number of dives, the counter will be reset to zero. This default value can be changed with a proper interface software program (optional). 4 Use of any safety factor.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 150 Related topics: • • • • • • 4.1.6. - Dive Computer Reset. 2.3.3. - Time and Date Adjustment. 2.3.4. - Unit of Measure Setting. 3.1. - DIVE WITH AIR. 3.3. - DIVE WITH NITROX. 4.1.2. - Dive Logbook. 4.1.5. - Data transfer to PC: PC-Interface compatible 4.1.5. - Data transfer to PC: PC-Interface compatible ( You can fully reset your dive computer, by pressing the small button with the “RESET” word on it (fig.
27-09-2005 16:17 Pagina 151 NOTE: Simulation speed is 6 times higher than in real life. In other words, 10 seconds in simulation mode correspond to 1 min. in a real life dive, with depth variations of 0.65ft at a time. Related topics: • • • • • • 2.3. - Parameter Setting. 2.3.3. - Time and Date Adjustment. 4.1.1. - Surface Interval Time. 4.1.2. - Dive Logbook. 4.1.3. - Dive History. 4.1.4. - Dive profile. Related topics: • • • • • • • • • • 4.2. - Simulator. 4.2.1.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 152 NOTE: Visually check the battery housing through its look-through cover. If you detect some signs of humidity inside, have the computer checked by a Service Center authorized by Cressi-sub. Related topics: • • • • • • • • • • 2.3. - Parameter Setting. 2.4. - Dive Planning 3.1. - DIVE WITH AIR. 3.1.1. - No Decompression Dive. 3.2.1. - Decompression Dive. 3.3. - DIVE WITH NITROX. 3.5. - CNS Toxicity Display. 3.6. - PO2 Alarms. 4.1.1. - Surface Interval Time. 4.2.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 153 by the arrows (fig. 33). Remove the cover and examine the battery and battery housing status: if you see signs of corrosion due to water infiltration, contact an Authorized Cressi-sub Service Center to check the computer. NOTE: Screw the battery cover back in place, Do not over tighten! Excessive tightening could break the cover or make it difficult to open again.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 154 THERMOMETER: - Resolution: 3.38°F; - Measuring range: 23 °F-104 °F; - Accuracy: +/- 35.6 °F. 6.1.1. - Non Decompression tables for the first dive in a series. Depth (m) CLOCK: Accuracy:+/- 30 sec on average per month; 24 hour display. Depth (ft) AIR EAN1 (32%) EAN2 (36%) (PO2=1.4bar) (PO2=1.4bar) 9 30 200 200 200 12 40 104 200 200 15 50 66 117 182 6.1. - DECOMPRESSION TABLES.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 155 7. - WARRANTY. The manufacturer guarantees Archimede Cressi-sub dive computer to be free from defects in materials and workmanship for a period of one year from the date in which it was first purchased. Damage deriving from improper use of the dive computer, failure to comply with maintenance provisions, negligence or adjustments/repairs carried out by service personnel not duly authorized by the manufacturer shall NOT be covered by the guarantee.
ARCHIMEDE 1 27-09-2005 16:17 Pagina 158 Archimede Flow Chart 158
ARCHIMEDE 1 27-09-2005 16:17 Pagina 159 159
Fig. 1 4 Fig. 1.a 1 5 2 Fig. 1.b Fig. 2 Fig. 1.c 6 1 3 7 2 6 7 4 1 3 Fig. 5 Fig. 6 Fig. 7 3 2 Fig. 7.1 Fig. 8 Fig. 15 Fig. 16 10 9 8 Fig. 4.b Fig. 4a Fig. 3 2 4 3 5 Fig. 9 Fig. 10 Fig. 11 Fig. 17 Fig. 18 Fig. 19 Fig. 22 Fig. 23 5 4 6 Fig. 12 Fig. 13 1 Fig. 14 3 1 4 2 Fig. 21 Fig. 20 1 2 8 5 1 7 4 Fig. 24 Fig. 25 Fig. 28 Fig. 29 1 1 3 2 2 3 6 3 4 4 3 2 Fig. 26 Fig. 31 Fig. 27 Fig.