Technical Specifications
21CRESTLINE SELECT 500 VINYL CLAD WINDOWS & PATIO DOORS
DOUBLE HUNG
Double Hung Window
Opening Specifications
Call Size
Sq. Ft. Clear
Opening
Clear Opening
Sq. Ft.
Daylight
Opening
Sq. Ft. Vent
Top of
Suboor to Top of
Sill Stop
a
Sq. Ft. Overall
Unit Area
b
Width Height
3030 2.875 31.625 13.090 5.367 2.875 48.063 8.75
3036 3.534 31.625 16.090 6.560 3.534 42.063 10.23
3040 4.193 31.625 19.090 7.753 4.193 36.063 11.71
3046 4.851 31.625 22.090 8.945 4.851 30.063 13.19
3048 5.071 31.625 23.090 9.343 5.071 28.063 13.68
3050 5.510 31.625 25.090 10.138 5.510 24.063 14.67
3050 (E) 5.702 31.625 25.965 10.138 5.702 24.063 14.67
3052 5.730 31.625 26.090 10.536 5.730 22.063 15.16
3056 6.169 31.625 28.090 11.331 6.169 42.063 16.15
3060 6.547 31.625 29.810 12.523 6.547 36.063 17.63
3066 6.547 31.625 29.810 13.716 6.547 30.063 19.11
3070 6.547 31.625 29.810 14.909 6.547 24.063 20.59
3149 (E) 5.728 33.375 24.715 10.230 5.728 26.563 14.74
3230 3.057 33.625 13.090 5.742 3.057 48.063 9.24
3236 3.757 33.625 16.090 7.018 3.757 42.063 10.81
3240 4.458 33.625 19.090 8.294 4.458 36.063 12.37
3246 5.158 33.625 22.090 9.570 5.158 30.063 13.93
3248 5.392 33.625 23.090 9.996 5.392 28.063 14.45
3250 5.859 33.625 25.090 10.846 5.859 24.063 15.49
3256 6.559 33.625 28.090 12.122 6.559 42.063 17.06
3260 6.961 33.625 29.810 13.398 6.961 36.063 18.62
3266 6.961 33.625 29.810 14.674 6.961 30.063 20.18
3270 6.961 33.625 29.810 15.951 6.961 24.063 21.74
3630 3.420 37.625 13.090 6.492 3.420 48.063 10.23
3636 4.204 37.625 16.090 7.935 4.204 42.063 11.96
3640 4.988 37.625 19.090 9.378 4.988 36.063 13.69
3646 5.772 37.625 22.090 10.820 5.772 30.063 15.42
3648 6.033 37.625 23.090 11.301 6.033 28.063 15.99
3650 6.556 37.625 25.090 12.263 6.556 24.063 17.15
3656 7.339 37.625 28.090 13.706 7.339 42.063 18.88
3660 7.789 37.625 29.810 15.148 7.789 36.063 20.61
3666 7.789 37.625 29.810 16.591 7.789 30.063 22.34
3670 7.789 37.625 29.810 18.034 7.789 24.063 24.06
4030 3.966 43.625 13.090 7.617 3.966 48.063 11.71
4036 4.874 43.625 16.090 9.310 4.874 42.063 13.69
4040 5.783 43.625 19.090 11.003 5.783 36.063 15.67
4046 6.692 43.625 22.090 12.695 6.692 30.063 17.65
4048 6.995 43.625 23.090 13.260 6.995 28.063 18.31
4050 7.601 43.625 25.090 14.388 7.601 24.063 19.63
4056 8.510 43.625 28.090 16.081 8.510 42.063 21.61
4060 9.031 43.625 29.810 17.773 9.031 36.063 23.59
4066 8.537 43.625 28.180 19.466 8.537 30.063 25.56
4070 8.537 43.625 28.180 21.159 8.537 24.063 27.54
Shaded sizes meet or exceed egress opening requirements per 2006 IBC (International Building Code) minimum dimensions of 20" clear opening width, 24" clear
openingheight,5.7sq.ft.clearopeningandoortobottomofclearopeningnottoexceed44".
a
Floor to bottom of clear opening dimensions are based on 82" header height.
Allunitsover66heightarebasedoff106"headerheightforoortoclearopeningdimension.
b
Sq. Ft. Overall Unit Area is calculated on the jamb dimension.
3050(E)and3149(E)haveaslightlymodiedsashportiontomeetegress.Topsashglassis17.50"tallerthanbottom.Sashstopmustberemovedtomeetegress
requirements.