- Crestron C2N-VEQ4 Volume Control Manual

Cresnet 4-Channel Digital Volume Control Crestron C2N-VEQ4
24 Cresnet 4-Channel Digital Volume Control: C2N-VEQ4 Operations Guide - DOC. 6135A
Filter Controls Symbol
Filter Controls Input Signals – Digital
NAME VALUE DEFINITION
SaveFilterPreset 1/0 Saves the current filter values into the
given FilterPreset# on the rising edge of
the signal.
RecallFilterPreset 1/0 Recalls the filter values from the given
FilterPreset# on the rising edge of this
signal.
Filter Controls Input Signals – Analog
NAME VALUE DEFINITION
FilterPreset# 1 to 5 5 user-definable filter presets, each of
which includes 48 filters
Filter# 1 to 48 Select filter (1-12 CH1; 13-24 CH2; 25-36
CH3; 37-48 CH4)
FilterType 0 to 5 0=off, 1=EQ, 2=High Pass, 3=Low Pass,
4=Treble Shelf, 5=Bass Shelf
FilterFreq 5 to 24000 5 Hz to 24 kHz Each analog increment
of 1 = 1 Hz
FilterQ 20 to 3500 0.02 to 3.5 octaves
Each analog increment of 1 = 0.001
octaves
FilterGain -360 to 240 -36 dB to +24 dB Each analog
increment of 1 = 0.1 dB
Filter Controls Symbol Output Signals – Analog
NAME VALUE DEFINITION
FilterType_FB 0 to 5 0=off, 1=EQ, 2=High Pass, 3=Low Pass,
4=Treble Shelf, 5=Bass Shelf
FilterFreq_FB 5 to 24000 5 Hz to 24 kHz, each analog increment
of 1 = 1 Hz
FilterQ_FB 20 to 3500 0.02-3.5 octaves, each analog
increment of 1 = 0.001 octaves
FilterGain_FB -360 to 240 -36 dB to +24 dB, each analog
increment of 1 = 0.1 dB