User Guide

Crestron SRD-SPL-4 Four-Way Amplified Splitter
Problem Solving
Troubleshooting
The table after this paragraph provides corrective action for possible
trouble situations. If further assistance is required, please contact a
Crestron customer service representative.
SRD-SPL-4 Installation Troubleshooting
TROUBLE
POSSIBLE
CAUSES
CORRECTIVE ACTION
With radio on and all
antenna cables connected
at the radio, check for 4 - 7
VDC at antenna end of
cable.
No signal
reception. Radio
display shows:
“Antenna
Disconnected”,
or “Acquiring
Signal”
Short circuits
or
discontinuities
With radios on and all
antenna cables connected
at the radios, check for AC
voltage at antenna end of
cable; should be < 1 VAC.
If AC voltage is found,
check for ground loops.
Ensure proper cable type
and length(s) per the block
diagram on page 2.
Ensure any amplifiers are
oriented properly with the
output (marked with an
arrow labeled Radio)
oriented towards the radio.
“Check
Antenna” or “No
Signal”
Antenna is
connected
properly but
signal is too
weak for
reception.
Refer to the instructions
supplied with the antenna
to ensure the antenna is
pointed accurately.
(Continued on following page)
Installation Guide – DOC. 6727A Four-Way Amplified Splitter: SRD-SPL-4 5