User Manual

Isys i/O
®
2.8” Handheld WiFi Touchpanel Crestron TPMC-3X
Setup
Identity Code
The IP ID is set within the TPMC-3X’s table using Crestron Toolbox™. For
information on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs
of multiple TPMC-3X devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the SIMPL™
Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.
Battery Installation
Perform the following procedure to install the TPMC-3X-BTP battery pack in a
TPMC-3X touchpanel:
1. Place the touchpanel screen side down on a clean, soft surface.
2. Remove the battery compartment cover on the rear of the touchpanel.
3. Carefully connect the multi-pin connector of the TPMC-3X-BTP with the
corresponding connector inside the battery compartment. The pin side of the
connector should be facing upward (toward the rear of the touchpanel). Red
wires should be above black wires (toward the top of the touchpanel).
Ensure the connector is fully seated.
4. Place the TPMC-3X-BTP in the battery compartment, oriented so the wires
for the multi-pin connector are on the bottom. Refer to the photo on the
following page.
12 Isys i/O
®
2.8” Handheld WiFi Touchpanel: TPMC-3X Operations Guide – DOC. 6789C