User's Manual

Crestron CEN-RFGW-EX infiNET EX™ Gateway
CEN-RFGW-EX Troubleshooting (Continued)
TROUBLE POSSIBLE
CAUSE(S)
CORRECTIVE
ACTION
infiNET EX device
RF ID does not
match the RF ID of
the SIMPL
program.
Use Crestron Toolbox
to poll the network.
Check the RF ID for
the device, then refer
to the “Setup” section
of the guide for the
device to set its RF ID
to match the RF ID in
the SIMPL program.
NET LED is on
but unit does not
communicate
with infiNET EX
device.
(Continued)
infiNET EX device
is not functioning
correctly.
Refer to the “Problem
Solving” section of the
guide for the device.
CEN-RFGW-EX is
in vicinity of metal.
Verify that large
amount of metal is not
in vicinity of
transmission.
infiNET EX device
is not functioning
correctly.
Refer to the “Problem
Solving” section of the
guide for the device.
Intermittent
response from
CEN-RFGW-EX
during
communication
with device.
infiNET EX device
is out of range.
Position the device
within operating range
or relocate
CEN-RFGW-EX. Refer
to “Specifications”
which starts on page 3
for details.
(Continued on following page)
Operations & Installation Guide – DOC. 6706B infiNET EX™ Gateway: CEN-RFGW-EX 21