User Manual

infiNET™ Thermostat Crestron CHV-TSTATRF
adjustment is 4 degrees per second (or 4 half degrees per second if “Half Degree
Setpoints” is set to true and the Temperature Scale is set to Celsius).
LDC Display Operation
CHV-TSTATRF LCD Display
C
F
HOLDAUTO
H
C
F
A
OFF
The LCD display on the CHV-TSTATRF will display the current ambient
temperature in degrees F or C (if the display is set to Fahrenheit or Celsius
respectively), except when the display is being used for other purposes such as
Setup.
The temperature display range is limited to -9º to 99ºF (-9º to 43ºC). If the ambient
temperature is above 99º, the display will indicate 99º. If the ambient temperature is
below -9º, the display will indicate -9º.
The display will show the current setpoint (in F or C) in whole degrees, except when
the System mode is Off or when the display is being used for other purposes such as
Setup.
While the setpoint is being adjusted, if it is set to a half-degree increment, the integer
portion of the number will be displayed and will alternate with “_5” every quarter
second for a period of four seconds after the last adjustment. After four seconds, only
the integer portion of the number will be displayed.
The display will show the “flame” icon when the System mode is Heat.
When you select Aux Heat Only mode (by pressing and releasing the MODE button
when System mode is Heat) the display will show “AU” in place of the ambient
temperature for as long as the button is held down or for two seconds (whichever is
greater). The display will flash the “flame” icon at a rate of on for two seconds and
off for a half second when the System mode is Aux Heat Only.
The “snowflake” icon is displayed when the System mode is Cool.
The “fan” icon is displayed at all times.
The “AUTO” element is displayed whenever the Fan setting is set to AUTO.
The “OFF” element is displayed when the System mode is Off.
The “H” element is displayed whenever a Heat Call is being made.
The “A” element is displayed whenever an Aux Heat Call is being made.
The “C” element is displayed whenever a Cool Call is being made.
The “F” element is displayed whenever a Fan Call is being made.
22 infiNET™ Thermostat: CHV-TSTATRF Operations & Installation Guide – DOC. 6490