Crestron BB-5000 Back Box Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc.
Crestron BB-5000 Back Box Contents Back Box: BB-5000 1 Description................................................................................................................................. 1 Installation ................................................................................................................................. 2 Construction Method ................................................................................................... 2 Post-Construction Method...................
Crestron BB-5000 Back Box Back Box: BB-5000 Description The back box, BB-5000, is the mounting hardware that secures either a Crestron Series 4500 or Series 5000 Lectern/Wall Mount Touchpanel to a wall or other suitable mounting surface.
Crestron BB-5000 Back Box Installation There are at least two different methods of installing the BB-5000. The construction method is initiated during the construction process. Use this method to wall mount either a Crestron Series 4500 or Series 5000 Lectern/Wall Mount Touchpanel to a wall stud. Installation begins at a time when the rooms in which the panel is to be installed are framed and the gypsum board has not been hung.
Crestron BB-5000 Back Box Securing Metal Electrical Box to Stud STUD SCREW HOLES 0.50 in (1.27 cm) 4. Use three #6 screws, not supplied, to secure metal electrical box to the stud. 5. Pull Cresnet wire through open knockout(s) in the metal electrical box. NOTE: Wait for gypsum board to be hung before continuing with remainder of construction method installation. 6. Fasten template, supplied, to mounting surface; cut out and remove the traced shape. 7.
Crestron BB-5000 Back Box 13. Tighten four screws installed in steps 10 and 12 by hand. Be careful not to crack gypsum board. 14. Verify that the rim of the back box is recessed approximately 1/8" from the mounting surface and tighten six screws installed in step 2 with a torque of 11 in-lbs (1.243 N*m). 15. If touchpanel is available, secure touchpanel to BB-5000 using eight pan head screws (1” length), supplied. Tighten screws by hand being careful not to crack gypsum board.
Crestron BB-5000 Back Box Securing Bracket/Plate Assembly to Top and Bottom Edges of Opening METAL MOUNTING BRACKET METAL MOUNTING PLATE TWO PAN HEAD SCREWS (MOUNTS BRACKET AND PLATE IN TWO CENTER TAPPED HOLES DRYWALL 10. Repeat steps 7 through 9 for the bottom horizontal edge of the opening. 11. Remove necessary knockout(s) from metal electrical box. 12. Pull Cresnet wire through open knockout(s) in metal electrical box. 13.
Crestron BB-5000 Back Box 14. Tighten four screws installed in steps 9 and 10 by hand. Be careful not to crack gypsum board. 15. Use six pan head screws (1/2” length), supplied, to loosely secure the back box to the bracket plate assembly. Securing Back Box to Bracket/Plate Assembly PAN HEAD SCREWS 0.125 in (0.317 cm) DRYWALL 16. Verify that the rim of the back box is recessed approximately 1/8" from the mounting surface before tightening the six pan head screws with a torque of 11 in-lbs (1.243 N*m).
Crestron BB-5000 Back Box Future Updates As Crestron improves functions, adds new features, and extends the capabilities of the BB-5000, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron website (www.crestron.com) periodically for manual update availability and its subjective value.
Crestron BB-5000 Back Box Cutout Detail of Supplied Template Use the alphanumeric codes in the illustration and tables to obtain the cutout dimensions for the BB-5000. However, Crestron recommends that the supplied template be used to avoid error. H1 H3 H5 H2 H4 H6 H8 V4 V5 R1 V1 V2 H7 H9 R2 V3 HORIZONTAL MEASUREMENTS H1 H2 H3 H4 H5 H6 = = = = = = 12.920 in (32.817 cm) 1.056 in (2.682 cm) 10.951 in (27.816 cm) 2.054 in (5.217 cm) 8.953 in (22.741 cm) 4.305 in (10.935 cm) H7 = 4.452 in (11.
Crestron BB-5000 Back Box Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Crestron BB-5000 Back Box This page intentionally left blank. 10 • Back Box: BB-5000 Installation Guide - DOC.
Crestron BB-5000 Back Box This page intentionally left blank. Installation Guide - DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Installation Guide – DOC. 5827A 05.02 Specifications subject to change without notice.