This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc.
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card Contents 2-Series IR/Serial Output Expansion Card: C2IR-8 1 Description................................................................................................................................. 1 Functional Description ................................................................................................ 1 Physical Description....................................................................................................
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card 2-Series IR/Serial Output Expansion Card: C2IR-8 Description Functional Description The C2IR-8 Infrared & Serial Output Expansion Card provides eight ports for infrared (IR), ASCII, or other serial communication and control. IR output is rated up to 1.2 MHz, at data rates up to 115K. Serial protocols include RS-232. This new generation card provides consistent IR data and generates output from all eight ports simultaneously.
2-Series IR/Serial Output Expansion Card Crestron C2IR-8 Leading Specifications The table below provides a summary of leading specifications for the C2IR-8. Leading Specifications of the C2IR-8 SPECIFICATION DETAILS Power Requirements IR Output RS-232 Data Rate Output Signal Levels 24 VDC, 0.125 A, 3 Watts Up to 1.2 MHz Up to 115K baud 0 to 5VDC (compatible with most RS-232 input devices) Crestron Application Builder™ Version 1.1 or later 2 Version 2.
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card Setup Installation Items required to install the C2IR-8 are already attached to the unit. The only tools required are a Phillips screwdriver and a grounding strap. Follow the assembly procedure below. CAUTION: The C2IR-8 contains electrostatic sensitive devices (ESD); observe precautions for handling ESDs to avoid damaging the card. NOTE: If installing the C2IR-8 into an AV2, it is assumed that CAGE2 has been installed. 1.
2-Series IR/Serial Output Expansion Card Crestron C2IR-8 Programming The C2IR-8 can be programmed using Crestron programming tools Crestron Application Builder™ (App Builder) and SIMPL™ Windows®. These tools are intended for users with different levels of programming knowledge. The flexibility of each tool is proportional to the degree of programming expertise (i.e., the more flexible, the more a programmer needs to know and account for).
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card Configure C2IR-8 Program DEVICE LIBRARY SYMBOL REQUIRED DROP WHERE ADDITIONAL SETUP Refer to the documentation supplied with the specific control system for additional setup information. CHANGE CARD SLOT (OPTIONAL) C2IR-8 System Plug-in Double-click on C2IR-8 to open the "Device Views, Control Card Settings" window. Select the CARD SLOT Cresnet tab and scroll to the desired slot location.
2-Series IR/Serial Output Expansion Card Crestron C2IR-8 Detail View of an IR Device Symbol in SIMPL Windows' Programming Manager Serial Port The symbol shown after this paragraph is only used when the card is used to communicate with a serial device. The port supports baud rates up to 115K. The tables that follow the symbol diagram list the inputs/outputs and their functional description. Input and outputs surrounded by brackets ([…]) are optional.
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card Problem Solving Troubleshooting The table below provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. C2IR-8 Troubleshooting TROUBLE C2IR-8 does not function. A particular IR device does not function. POSSIBLE CAUSE(S) 2-Series Control System is not receiving power. Circuit card is not properly seated in slot. Programming error.
2-Series IR/Serial Output Expansion Card Crestron C2IR-8 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card This page intentionally left blank. Operations & Installation Guide – DOC.
2-Series IR/Serial Output Expansion Card Crestron C2IR-8 This page intentionally left blank. 10 • 2-Series IR/Serial Output Expansion Card: C2IR-8 Operations & Installation Guide – DOC.
Crestron C2IR-8 2-Series IR/Serial Output Expansion Card This page intentionally left blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 8172 12.01 Specifications subject to change without notice.