Crestron C2N-DEMO Lighting Case Reference Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names, and trademarks are the property of their respective owners. ©2004 Crestron Electronics, Inc.
Crestron C2N-DEMO Lighting Case Demonstration Case Contents Crestron Demonstration Case: C2N-DEMO Lighting Case 1 Introduction ............................................................................................................................... 1 Features and Functions................................................................................................ 1 Case Contents ..............................................................................................................
Crestron C2N-DEMO Lighting Case Demonstration Case Crestron Demonstration Case: C2N-DEMO Lighting Case Introduction Features and Functions The Crestron® C2N-DEMO Lighting Case (herein known as the Lighting Case) is a pre-programmed Crestron system in a portable case. It is designed with the sales person in mind to give customers a basic understanding of Crestron automation and lighting systems.
Demonstration Case Crestron C2N-DEMO Lighting Case Case Contents The following table summarizes the products contained within the Lighting Case.
Crestron C2N-DEMO Lighting Case Demonstration Case “Internet Protocol (TCP/IP) Properties” Window Click on OK to exit and save settings. NOTE: The PAC2 utilizes a dual port Ethernet card with firewall enabled. Use this as a point for discussions regarding system security. Refer to step 4 for accessing a web page through a firewall. 3. Ethernet Cable Connect the supplied Ethernet cross-over cable between the Lighting Case Ethernet port (marked LAN A) and the Ethernet port on your laptop.
Demonstration Case Crestron C2N-DEMO Lighting Case System Functionality This section describes each interface and how it is intended to function. This information should be useful in how you approach your sales presentation, enabling you to concentrate on the features most relevant to your customer. Since this system was programmed in D3 Pro, it is important to understand what features are available as they apply to each interface. The first thing to examine is the way buttons can be programmed.
Crestron C2N-DEMO Lighting Case Demonstration Case Multi-Press The multi-press button model triggers different actions each time the button is pressed, to a maximum of 10 button presses. If the button is not pressed after a specified period, a timeout event occurs and the button resets. Thus, the next button press triggers the first event. A timeout is also an event that can trigger actions.
Demonstration Case Crestron C2N-DEMO Lighting Case Always Off The button’s feedback is always inactive (e.g., LED is never illuminated). Momentary The button’s feedback is active while the button is being pressed and inactive when the button is released. On when ANY light in preset is ON The button’s feedback is active if any of the lights assigned to the button’s press or tap event are above 0%.
Crestron C2N-DEMO Lighting Case Demonstration Case CNX-B2 (Dining Room) 1.536 1.5360" 2.9119" 2.912 1.067 1.0670" 4.762 4.7619" DINNER PARTY MUSIC This interface was programmed as a secondary interface for the dining room in this system. The entire virtual house can be monitored from the web page project associated with this system.
Demonstration Case Crestron C2N-DEMO Lighting Case This interface was programmed as a secondary interface for the master bedroom. The entire virtual house can be monitored from the web page project associated with this system. Button 1 (LIGHTS) [BM = Toggle + Dim, FB = Toggle, Loads = Master Bed Downlights, Master Bed Downlights2] On press 1, this button turns on all loads to a preset level and then off again on press 2.
Crestron C2N-DEMO Lighting Case Demonstration Case Button 1 (MORNING) [BM = Single Press / Learnable, FB = On when ALL lights are at PRESET LEVEL, Loads = Bath Vanity, Bath Downlights] When this button is pressed, it turns on all loads to a preset level over a defined period. Button 2 (EVENING) [BM = Single Press / Learnable, FB = On when ALL lights are at PRESET LEVEL, Loads = Bath Vanity, Bath Downlights] When this button is pressed, it turns on all loads to a preset level over a defined period.
Demonstration Case Crestron C2N-DEMO Lighting Case This interface was programmed as the primary control point for the dining room. The entire virtual house can be monitored from the web page project associated with this system. Button 1 (DINNER PARTY) [BM = Single Press / Learnable, FB = On when ALL lights are at PRESET LEVEL, Loads = Dining Chandelier, Dining Downlights, Dining Sconce] When this button is pressed, it turns on all loads to a preset level over a defined period.
Crestron C2N-DEMO Lighting Case Demonstration Case CNX-B12 (Master Bathroom) 1.536 2.912 2.9119" MORN DOWN NOON VANITY EVEN CLOSETS RELAX FAN MUSIC VOL + SOURCE VOL - 1.067 1.0670" 4.762 4.7619" 1.5360" This interface was programmed as the primary control point for the master bathroom. The entire virtual house can be monitored from the web page project associated with this system. NOTE: The CNX-B12 is designated for the master bathroom and the CNX-B2 is designated for the dining room.
Demonstration Case Crestron C2N-DEMO Lighting Case Button 5 (EVEN) [BM = Single Press / Learnable, FB = On when ALL lights are at PRESET LEVEL, Loads = Bath Vanity, Bath Ceiling Lights, Bath Downlights] When this button is pressed, it turns on all loads to a preset level over a defined period. Button 6 (CLOSETS) [BM = Toggle + Dim, FB = Toggle, Loads = Bath Ceiling Lights] On press 1, this button turns the load to a preset level and then off again on press 2.
Crestron C2N-DEMO Lighting Case Demonstration Case C2N-DB6 (Family Room) 4.158 FRONT LAMP REAR FAN FAMILY PARTY 1.067 1.696 2.696 1.788 1.532 This interface was programmed as the primary control point for the family room. The entire virtual house can be monitored from the web page project associated with this system. Button 1 (FRONT) [BM = Toggle + Dim, FB = Toggle, Loads = Front Downlights] On press 1, this button turns the load to a preset level and then off again on press 2.
Demonstration Case Crestron C2N-DEMO Lighting Case Chandelier, Bath Vanity, Bath Downlights, Breakfast Chandelier, Dining Room Lights, Hall 1 Lights, Hall 2 Lights, Front Porch] When this button is pressed, it turns all loads to a preset level over a defined period. If it is past sunset, the front porch light illuminates as well. C2N-DB8 (Entry) 4.158 HOME AWAY PATH PORCH MUSIC VOL + SRC VOL - 1.067 1.696 2.696 1.788 1.
Crestron C2N-DEMO Lighting Case Demonstration Case Button 5 (MUSIC) This button toggles the audio system in the common areas of the virtual home on and off. The feedback LED illuminates when the audio system is active. Button 6 (VOL +) This button increases the volume level of the virtual audio system. The feedback LED illuminates only while the button is pressed. Button 7 (SRC) This button cycles through the various virtual audio sources. The feedback LED illuminates only while the button is pressed.
Demonstration Case Crestron C2N-DEMO Lighting Case Button 3 (LAMP) [BM = Toggle + Dim, FB = Toggle, Loads = Lamp] On press 1, this button turns the load to a preset level and then off again on press 2.
Crestron C2N-DEMO Lighting Case Demonstration Case Appendix: Factory Settings The C2N-DEMO Lighting Case ships completely configured. In the event that the original factory settings are altered, corrupted, or erased, the following information is necessary for reconfiguring the processor in each case. C2N-DEMO Interface Case: • IP address is 192.168.40.11 • Subnet mask is 255.255.255.0 • Default router is 192.168.40.10 C2N-DEMO Lighting Case: LAN A • IP address is 192.168.1.2 • Subnet mask is 255.
Demonstration Case Crestron C2N-DEMO Lighting Case Details on NAT can be found in the latest version of the NAT Reference Guide (Doc. 6001), which can be found on the Downloads | Product Manuals page of the Crestron website (www.crestron.com). 18 • Crestron Demonstration Case: C2N-DEMO Lighting Case Reference Guide – DOC.
Crestron C2N-DEMO Lighting Case Demonstration Case Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Reference Guide – DOC. 6282 09.04 Specifications subject to change without notice.