Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Contents FlipTop Control Center, Dual AC Outlets: C2N-FTB-D 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Internal Block Diagram ...............................................................................................
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets FlipTop Control Center, Dual AC Outlets: C2N-FTB-D Introduction Features and Functions The C2N-FTB-D provides an ingenious control and connectivity solution in a stylish flush mount tabletop package. Simply flip open the “FlipTop” lid to expose a pushbutton keypad, perfectly angled for easy access and operation.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D and other parameters. To prevent accidental button presses, the keypad is automatically disabled whenever the lid is not fully opened. Cable Storage Compartment The C2N-FTB-D also provides for extensive connectivity through an easy pull-out cable storage mechanism to support a wide range of applications and signal types.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets C2N-FTB-D Specifications (Continued) SPECIFICATION DETAILS Black painted metal with black anodized or brushed aluminum cover; flush tabletop mountable Enclosure Environmental Temperature 41º to 104ºF (5º to 40ºC) Humidity 10% to 90% RH (non-condensing) Heat Dissipation 6 BTU/Hr Dimensions Height 5.39 in (13.69 cm) with lid closed Width 6.75 in (17.14 cm) Depth 5.71 in (14.50 cm) Weight 3.75 lbs (1.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Physical Description This section provides information on the connections, controls and indicators available on your C2N-FTB-D. C2N-FTB-D Physical View C2N-FTB-D Overall Dimensions (Top View) 6.75 in (17.14 cm) 5.08 in (12.89 cm) 5.71 in (14.50 cm) 4 • FlipTop Control Center, Dual AC Outlets: C2N-FTB-D Operations & Installation Guide – DOC.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets C2N-FTB-D Overall Dimensions (Front View) C2N-FTB-D Overall Dimensions (Bottom View) 5.16 in (13.10 cm) 6.25 in (15.87 cm) C2N-FTB-D Overall Dimensions (Rear View) C2N-FTB-D Overall Dimensions (Side View) 2.32 in (5.88 cm) 4.32 in (10.96 cm) 5.39 in (13.69 cm) 4.58 in (11.63 cm) 5.21 in (13.23 cm) Operations & Installation Guide – DOC.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D C2N-FTB-D Connectors, Controls & Indicators (Top View) 1 2 4 3 5 C2N-FTB-D Connectors, Controls & Indicators (Bottom View) 6 6 • FlipTop Control Center, Dual AC Outlets: C2N-FTB-D 7 8 9 Operations & Installation Guide – DOC.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Connectors, Controls & Indicators * # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 1 KEYPAD Programmable keypad allowing variable combinations of large and small engravable buttons, 10 minimum (all large) to 20 maximum (all small); ships with 10 large buttons (small buttons and engraving sold separately) (1) red LED per button, programmable. 2 PWR (1) Green LED, indicates 24 Volts DC power supplied from Cresnet control network.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Industry Compliance As of the date of manufacture, the C2N-FTB-D has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Setup Network Wiring When wiring the Cresnet® network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Button Installation The C2N-FTB-D is shipped with ten large blank buttons. You can order a variety of button kits (sold separately) for a total of 20 engraved or blank buttons.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Cable Support Plate The C2N-FTB-D is shipped with a cable support plate that provides an easy pullout cable solution for the computer input and LAN pass through cables. Parts Supplied for Cable Support DESCRIPTION PART NUMBER QUANTITY 2011563 1 Cable Bushing, 0.55” ID, 0.80” OD 2010496 2 Cable Bushing, 0.39” ID, 0.64” OD 2011070 2 Cable Support Plate Cable Bushing, 5/16“ ID, 0.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D When selecting cables for installation in the C2N-FTB-D, cable connector length and strain relief diameter are important considerations. • If the connector is too long, it can interfere with cover operation and scratch the buttons. • If the width of the cable strain relief is too similar to the bushing inside diameter, the bushing can trap the cable. NOTE: Do not use the cable support plate without the bushings.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Mounting to Surface The C2N-FTB-D is designed to mount in a horizontal surface such as a desk top, lectern or podium. The following diagram illustrates the required opening size to accommodate the C2N-FTB-D. A cutout template (4010018) is included.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Mounting Bracket Screw Locations 3. Install the four #10 screws in the mounting brackets (two screws per bracket). Refer to the following diagram. 4. Slide the mounting brackets over the #6-32 screws and tighten all eight #6-32 screws. 5. Turn the four #10 screws equally until they contact the underside of the mounting surface. NOTE: Do not over-tighten the #10 screws as this may damage the surface and/or the unit.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets NOTE: Be careful not to press the buttons while closing the FlipTop, even though the buttons are disabled when the FlipTop begins to close and all pressed buttons are released. Hardware Hookup Connect the Device Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 9 before attaching the 4-position terminal block connector. Apply power after all connections have been made.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D NOTE: The maximum continuous current from equipment under any external load conditions shall not exceed a current limit that is suitable for the minimum wire gauge used in interconnecting cables. The ratings on the connecting unit's supply input should be considered to prevent overloading the wiring. NOTE: Ensure the unit is properly grounded. Ground Wire Connections Proper grounding is required.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com. First-time users will need to establish a user account.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Locating the C2N-FTB in the Device Library • The system tree of the control system displays the device in the appropriate slot with a default Net ID as shown in the following illustration. C2Net Device, Slot 9 • Additional C2N-FTB-D devices (shown as C2N-FTB) are assigned different Net ID numbers as they are added.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets “C2N-FTB Device Settings” Window • Program Manager The ID code specified in the SIMPL Windows program must match the Net ID of each unit. Refer to “Identity Code” on page 9. Program Manager is the view where programmers “program” a Crestron control system by assigning signals to symbols. The symbol can be viewed by double clicking on the icon or dragging it into Detail View.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Upgrade C2N-FTB-D firmware via Crestron Toolbox. • Establish communication with the C2N-FTB-D and display the “System Info” window. • Select Functions | Firmware… to upgrade the C2N-FTB-D firmware. Program Checks Using Crestron Toolbox, display the network device tree (Tools | Network Device Tree) to show all network devices connected to the control system. Right-click on the C2N-FTB-D to display actions that can be performed on the C2N-FTB-D.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. C2N-FTB-D Troubleshooting TROUBLE C2N-FTB-D is not functioning. POSSIBLE CAUSE(S) CORRECTIVE ACTION Net ID is incorrect. Verify the Net ID in Toolbox. Net ID is not set to match the Net ID specified in SIMPL Windows.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets When calculating the length of wire for a particular Cresnet run, the wire gauge and the Cresnet power usage of each network unit to be connected must be taken into consideration. Use Crestron Certified Wire only. If Cresnet units are to be daisychained on the run, the Cresnet power usage of each network unit to be daisychained must be added together to determine the Cresnet power usage of the entire chain.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Future Updates As Crestron improves functions, adds new features and extends the capabilities of the C2N-FTB-D, additional information may be made available as manual updates.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
FlipTop Control Center, Dual AC Outlets Crestron C2N-FTB-D This page is intentionally left blank. 26 • FlipTop Control Center, Dual AC Outlets: C2N-FTB-D Operations & Installation Guide – DOC.
Crestron C2N-FTB-D FlipTop Control Center, Dual AC Outlets This page is intentionally left blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6639B (2019708) 04.08 Specifications subject to change without notice.