Identity Code
Every network device and user interface within the Cresnet network
requires a unique identity code (Net ID). These codes are two-digit
hexadecimal numbers from 03 to FE. The Net ID of each unit must match
an ID code specified in the SIMPL Windows program. Refer to “Setting
the Net ID in Device Settings” on page 25 for details of the SIMPL
Windows procedure.
The Net ID of the C2N-MNETGW has been factory set to 0F. The Net
IDs of multiple C2N-MNETGW devices in the same system must be
unique. Net IDs are changed from a personal computer (PC) via the
Crestron Toolbox.
NOTE: For detailed information on establishing communication
between the PC, control system, and the C2N-MNETGW, refer to
“Establishing Communications” on page 27. If communication cannot be
established, refer to the “Troubleshooting Communications” section in
the latest version of the 2-Series Control System Reference Guide
(Doc. 6256), which is available from the Crestron website
(http://www.crestron.com/manuals).
The Crestron Toolbox provides several methods to easily set or change
device Net IDs for any device on the network. The following method
permits you to change the Net ID of any device in the network through
the “Network Device Tree” window.
This method permits you to manually set the Net ID for any device in the
network, set any known Net IDs that may require changing, and may also
be used for non-TSID equipment. This method will not permit you to
choose an ID already in use by another device that is not equipped with
TSID. A warning message will appear if you attempt to use an ID that is
already in use by a device that is equipped with TSID.