Crestron CHV-TSTATEX-FCU ® infiNET EX Thermostat (Fan Coil Unit) Operations & Installation Guide
Regulatory Compliance As of the date of manufacture, the CHV-TSTATEX-FCU has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Contents infiNET EX Thermostat (Fan Coil Unit): CHV-TSTATEX-FCU 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications ...................................................................................................
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) infiNET EX Thermostat (Fan Coil Unit): CHV-TSTATEX-FCU Introduction The CHV-TSTATEX-FCU is a wireless thermostat featuring infiNET EX® technology. The CHV-TSTATEX-FCU installs just like a conventional thermostat because no extra wires are needed to connect to the control system. Although functional as a standalone thermostat, the CHV-TSTATEX-FCU delivers enhanced functionality as part of a complete Crestron® automation system.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Fan Coil Unit Support The CHV-TSTATEX-FCU infiNET EX thermostat provides the functionality of controlling fan coil units1. The CHV-TSTATEX-FCU has custom firmware, display programming and terminal labels designed for 3-speed fan applications. The CHV-TSTATEX-FCU supports on/off control of the valves and the fan in 4-pipe fan coil applications, eliminating the need for an additional device dedicated to controlling the fan coil unit itself.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Remote Sensors Optional remote temperature sensors can be connected to the CHV-TSTATEX for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTATEX to be installed out of view. For heat pump-type systems, outdoor temperature can be monitored to optimize system performance.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU CHV-TSTATEX-FCU Specifications (Continued) SPECIFICATION DETAILS Power Requirements 24V 0.24 watts (10 mA @ 24 volts ac) supplied by heating or cooling system Battery Two AA batteries, estimated 1 year normal operation Default RF ID 01 Housing Injection molded plastic, surface mountable to the front of a horizontally oriented 1-gang electrical box. Dimensions Height 4.50 in (115 mm) Width 5.53 in (141 mm) Depth 1.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Physical Description This section provides information on the connections, controls and indicators available on the CHV-TSTATEX-FCU. CHV-TSTATEX-FCU Physical View CHV-TSTATEX-FCU Overall Dimensions (Front and Side Views) 5.53 in (141 mm) 1.03 in (26 mm) 1 3 2 4 4.50 in (115 mm) 5 Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) CHV-TSTATEX-FCU Overall Dimensions (Rear View) 3 .27 in (83 mm) CHV-TSTATEX-FCU (Connection View, Front with Cover Removed) RSR RSR N/C W GH N/C Y R N/C RS1 GM 6 • infiNET EX Thermostat (Fan Coil Unit): CHV-TSTATEX-FCU 24C RS2 GL 6 Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) STEAL 1 2 3 4 1 2 3 4 ON ON CHV-TSTATEX-FCU (DIP Switch and Power Switch View) 24 VAC Connectors, Controls & Indicators # CONNECTORS, CONTROLS & INDICATORS 1 MODE Button 2 FAN Button 3 DESCRIPTION Cycles through available system modes: OFF, HEAT, AUTO and COOL Toggles fan setting between FAN AUTO and FAN ON Raises the setpoint 4 Lowers the setpoint 5 LCD Display 6 HVAC Displays ambient temperature, setpoint, system mode,
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Connectors, Controls & Indicators (Continued) # CONNECTORS, CONTROLS & INDICATORS 7 HVAC DESCRIPTION (7) terminal blocks.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Setup Identity Code NOTE: The latest software can be downloaded from the Crestron Web site (www.crestron.com/software). Every CHV-TSTATEX-FCU communicating via RF with a Crestron control system through a CEN-RFGW-EX wireless gateway or directly with an MC3 3-Series Control System requires a unique RF ID. The RF ID is a two-digit hexadecimal number that can range from 03 to FF.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) 3. Feed HVAC wiring from the electrical box through the hole in the center of the rear plate so it can be connected to the proper terminals on the CHV-TSTATEX-FCU after the thermostat is mounted. CAUTION: Excess wire pinched between the CHV-TSTATEX-FCU and electrical box could cause a short circuit. Make sure that all excess wire is completely inside the electrical box and not between the box and the CHV-TSTATEX-FCU.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) DIP Switch Setup The following describes the CHV-TSTATEX-FCU DIP switch settings. 1. Install two AA batteries (included) in the battery compartment. 2. Locate the DIP switches inside the unit and configure the parameters per the tables below.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU NOTE: Steal Power mode may cause problems with some types of HVAC systems, such as indicating a false heat or cool call. If this occurs, do not use Steal Power mode. If the thermostat will be wired so that 24 volts ac are always be present on the 24C terminal, slide the POWER switch to 24VAC. No batteries are required in this mode.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Connections for the CHV-TSTATEX-FCU NOTE: 24 volt power is returned through the R connector. Refer to wiring diagrams on the following pages. NOTE: Refer to “DIP Switch Setup” which starts on page 11 for DIP switch settings. Operations & Installation Guide – DOC.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU CHV-TSTATEX-FCU Wiring Diagram W N/C N/C RSR RSR RS2 RS1 Heat Pipe Valve Cool Pipe Valve 24C R Y N/C GH GL GM Fan High Relay Fan Med Relay Fan Low Relay System Transformer C Optional R 14 • infiNET EX Thermostat (Fan Coil Unit): CHV-TSTATEX-FCU Operations & Installation Guide – DOC.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) CHV-TSTATEX-FCU Sensor Wiring Operations & Installation Guide – DOC.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Basic Setup Basic Thermostat Setup The following describes the most common setup requirements. For full details on all setup options, refer to “Advanced Setup” which starts on page 18. Place the CHV-TSTATEX-FCU in the Setup mode by doing the following: 1. Press and hold the FAN button. 2. While the FAN button is being held, press and hold the simultaneously. 3. Hold all three buttons for 5 seconds, after which the unit enters Setup mode.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) 2. Ensure the unit is in Setup mode (refer to “Basic Setup - Basic Thermostat Setup” above or “Setup Mode” which starts on page 18) and that Acquire mode (AC) is selected. 3. Press MODE until the “infiNET EX ID” function is displayed (id). Use and to choose the infiNET EX ID. 4. Press MODE until the “Start infiNET EX Acquire” function is displayed (AC). 5.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Advanced Setup Setup Mode After the CHV-TSTATEX-FCU is installed, it is necessary to set it up for a particular heating/cooling system. Please note that some of the setup parameters listed below are not always shown since they are dependent upon other thermostat settings. Refer to “Setup Mode Parameters/Functions”, which starts on page 19 for details. Place the CHV-TSTATEX-FCU in the Setup mode by doing the following: 1.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) NOTE: While in Setup mode, a period of one minute with no button activity causes the CHV-TSTATEX-FCU to revert to standard operation, unless a function (such as an infiNET EX acquire) is executing. Setup Mode Parameters/Functions The following table shows the available setup parameters/functions.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION CODE VALID VALUES DEFAULT VALUE Remote sensors Sn i, r, ir i i – internal sensor only (When no remote sensor is detected, only this option is available); r – remote sensor only (Only available when a remote sensor has been detected); ir – average internal and remote sensors Check Firmware Version rE Firmware version is displayed in xx.yy.zz format.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Setup Mode Parameters/Functions (Continued) PARAMETER/ FUNCTION DEFAULT VALUE CODE VALID VALUES Perform Heat Call Test (Toggle) H Not started/Heat call off (--) Heat call on (on) (also, “H” icon turns on) N/A Tests the heat call output; Bypasses short-cycle timers; Useful for technician system testing; Note that calling the heat may activate other relays in the thermostat as required, such as the fan output for heat pump or dual-fuel
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Self-Test Results These error/status codes are returned when performing a self-test operation, enter Setup mode as described in “Basic Thermostat Setup” which starts on page 16. Press MODE until the AC, UA or CC function is displayed. Press or on the CHV-TSTATEX-FCU to verify the communication status. Self-Test Error Codes ERROR CODE SUMMARY CORRECTIVE ACTION REMARKS 00 Success None No detectable problems found.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Operation System Mode The MODE button on the CHV-TSTATEX-FCU cycles the unit through all available system modes in the following order: Off, Heat, Emergency Heat (for heat pump and dual-fuel systems), Cool and Auto (if enabled in Setup). The system mode changes upon release of the MODE button and the selected mode becomes operational 5 seconds after the mode has been entered. Off Mode In Off mode, all HVAC systems are disabled.
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Dual Setpoint Auto Mode (“AU” = “d” in Setup Mode) In dual setpoint Auto mode, separate heat and cool setpoints are used. When the ambient temperature drops below the heat setpoint, the unit calls for heat to maintain the heat setpoint. When the ambient temperature rises above the heat setpoint, the unit does not call for cooling until the temperature exceeds the cool setpoint.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) If the or button is held down for 2 seconds, the unit enters an auto-repeat state and the setpoint adjusts rapidly until the button is released or until the upper (or lower) limit is reached. Some users want to have setpoints change automatically based on the day of the week and the time of day. For example, in the winter they may want to lower the heat setpoint while they sleep to lower heating costs.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) screen. Instead, the thermostat wakes up shortly after the last button press to send its updated status to the control system. If the thermostat is wired to have the optional 24 Vac at the 24C terminal and the power switch is set for 24 V, there is no delay in feedback.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) LCD Display Elements * # LCD DISPLAY ELEMENT DESCRIPTION 1 Large 7-segment digits Indicates current ambient temperature*.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (or device).
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) connecting to the MC3, refer to the latest version of the MC3 3-Series Control System Operations Guide (Doc. 7095). Programs and Firmware Program or firmware files may be distributed from programmers to installers or from Crestron to dealers. Firmware upgrades are available from the Crestron Web site as new features are developed after product releases.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CHV-TSTATEX-FCU Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION No power from system. Check for 24 Vac on 24C connector. Check circuit breaker powering furnace or boiler. Check thermostat wiring.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) CHV-TSTATEX Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION System cycles too quickly. Anticipator setting is too low. Reprogram anticipator setting (refer to “Setup Mode Parameters/Functions” which starts on page 19). Poor battery life. Ensure that the power switch selection position is proper for the expected conditions.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) CHV-TSTATEX Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) Wrong temperature is displayed. Wrong temperature scale. Select F or C as necessary. A Temperature Offset has been applied. Reset Temperature Offset (refer to “Setup Mode Parameters/Functions” which starts on page 19). Bad location. Ensure the thermostat is located away from direct sunlight, drafts, doorways, skylights and windows or exterior walls.
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Reference Documents The latest version of all Documents mentioned within the guide can be obtained from the Crestron Web site (http://www.crestron.com/manuals).
infiNET EX Thermostat (Fan Coil Unit) Crestron CHV-TSTATEX-FCU Glossary Anticipators Used to anticipate the drop or rise in temperature and energize the appropriate system before reaching the setpoint. Anticipators affect how tightly the setpoint temperature is maintained. Auto Dead Band Sets the minimum separation in auto mode between heat and cool setpoints (with dual setpoints) or maximum drift before system latches alternate mode (with single setpoint).
Crestron CHV-TSTATEX-FCU infiNET EX Thermostat (Fan Coil Unit) Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 7206C (2031609) 01.13 Specifications subject to change without notice.