Crestron CLS/CLSI-C6 & CLS/CLSI-C6M ® iLux Integrated Lighting System Operations Guide
Regulatory Compliance This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc. As of the date of manufacture, the CLS-C6, CLS-C6M, CLSI-C6, and CLS-C6M have been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Contents iLux Integrated Lighting System: CLS/CLSI-C6 & CLS/CLSI-C6M 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Specifications .........................................................................................
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Room Combining Commands ................................................................................... 67 Override Commands .................................................................................................. 67 Load Shed Commands ............................................................................................... 68 Occupancy Commands ..........................................................................
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System iLux Integrated Lighting System: CLS/CLSI-C6 & CLS/CLSI-C6M Introduction The CLS/CLSI-C6 and CLS/CLSI-C6M iLux® units are complete, integrated wall-mounted lighting systems that can function as standalone devices or as part of a Crestron® solution total control system network.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Features and Functions (Continued) • • • • Energy saving ASHRAE 90.1/LEEDS compliant Available in almond, black, or white Supports daylight harvesting RS-232 interface via C2N-IO (sold separately) Six Channel Dimming The CLS-C6 features six channels of dimming for LED*, incandescent, magnetic low-voltage, neon/cold cathode, and 2-wire dimmable fluorescent loads. On/off switching of many non-dimmable lighting loads is also possible.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Built-in Motion Detector (CLS-C6M and CLSI-C6M) The CLS-C6M and CLSI-C6M models provide the addition of a built-in infrared motion detector, enabling automated control based on room occupancy. Lights can be programmed to turn on and shades open automatically when someone enters the room or turn off and close when the room is left empty.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Building Management System Integration Crestron CLS-C6 includes BMS integration capabilities for straightforward inclusion of building management systems as a component of managing energy demands. Control System Integration The CLS-C6 actually features two separate Cresnet control networks, one for local devices and one for connection to a 2-Series control system.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System CLS-C6 Specifications (Continued) SPECIFICATION DETAILS Power Requirements CLS-C6/C6M Line Power, 100–127 Vac, 50/60 Hz CLSI-C6/C6M Line Power, 220–240 Vac, 50/60 Hz Default Net ID 1F IR Receiver Reception Frequency Built-In Motion Detector (CLS/CLSI-C6M only) Type Range 36 kHz Requires CLS-IRHT8 IR remote (sold separately). Infrared 20 to 30 feet at 4 foot elevation (6 to 9 meters at 1.2 meter elevation) Firmware v2.01.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M CLS-C6 Specifications (Continued) SPECIFICATION DETAILS Available Accessories (Continued) 1. 2.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System CLS-C6M Overall Dimensions 2.38 in (60 mm) 8.89 in (226 mm) 4.48 in (114 mm) ^ ^ 1.88 in (48 mm) 0.59 in (15 mm) CLS-C6/ CLSI-C6 0.72 in (18 mm) CLS-C6M/ CLSI-C6M CLS-C6M Front Panel 1 2 3 4 5 6 Min Sec ^ ^ Scene 1 Scene 2 Scene 3 Scene 4 Scene 5 Scene 6 ^ ON ^ OFF Operations Guide – DOC.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M CLS-C6 Rear Panel Connectors, Controls, and Indicators * # CONNECTORS , CONTROLS, AND INDICATORS DESCRIPTION 1 Bar Graphs In Standard mode and Lights mode, the bar graphs, each a series of seven LEDs, indicate the current light intensity for the six lighting loads. When under photocell control, the top bar graph LED for a controlled load blinks. In Shades mode, they indicate the shade position for each of the shade groups.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Connectors, Controls, and Indicators (Continued) * # CONNECTORS , CONTROLS, AND INDICATORS DESCRIPTION 7 2-Digit Display In Standard mode, the display is normally blank, except when showing scene fade time. The Min and Sec LEDs illuminate when the display is indicating time in minutes or in seconds, respectively.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Connectors, Controls, and Indicators (Continued) * * # CONNECTORS , CONTROLS, AND INDICATORS 16 LOAD1–LOAD6 Use these terminals to connect the CLS-C6 dimmer channel outputs to the appropriate lighting loads. 17 HOT, NEUTRAL, (Ground) Use these terminals to connect the unit to the 120 V (CLS-C6/M) or 230 V (CLSI-C6/M) power source.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Setup Network Wiring When wiring the Cresnet network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Configuring the CLS-C6 The overall configuration of the CLS-C6 can be accomplished in two ways: using the front panel controls or using the supplied iLux Designer application software, which can be downloaded from the Crestron Web site. Configuring via the front panel controls is not as extensive as what can be done using the iLux Designer but permits basic functional setup without having to use a PC.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System light (and the display shows “– –”) to indicate that the level of the lighting load does not change when that scene is recalled. 5. To change the shade presets for that scene press the Shades button; the Shades LED lights. 6. Use the six function buttons to adjust the levels of the shade groups for that scene. Press the right side to raise the shades; press the left side to lower them.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Setup Option Mnemonics 2-DIGIT DISPLAY Sc Ld LE HE Lo bF ud oc Ad AS id Ph Pc PL Pr Fd Er DESCRIPTION Scene Programming Setup lighting Load types Setup lighting load Low-End limits Setup lighting load High-End limits Setup Lockout mode button Functions (i.e., recall scene, toggle scene, shades control, etc.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System while the display is at a level below the LE limit or above the HE limit, the displayed value is saved but the light level is limited to the programmed limits. • If a lighting load is defined as an unused load type, the bar graph for that lighting load has all LEDs off. If the lighting load is adjusted, the 2-digit display shows “Er.” • To mark a lighting load as not affected (i.e.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Lighting Load Type Setup Load Type Unused Number 0 LEDs all off Default Low-End/ High-End 0 / 100 Incandescent – default 1 top 1 on 0 / 100 MLV 2 top 2 on 0 / 100 NCC 3 top 3 on 0 / 100 Fluorescent (2-wire) 4 top 4 on 10 / 100 Non-dim (On at start/Off at start)¹ 5 top 5 on 0 / 100 Non-dim (On at end/Off at start)² 6 top 6 on 0 / 100 1. Whether going on or off, this load type switches at the start of the fade.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Setup High-End Levels (HE) This option allows setting of the full on level of the lighting loads below their maximum brightness. To set the high-end levels for the six lighting loads, see below: • Enter Setup mode and scroll to the “HE” option (using the and buttons). At this point the lights do not change but the bar graphs immediately indicate the high-end levels for each lighting load.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M that button. When the button is released, the LED for that button should flash once to indicate that programming took place. 2. Next, use the up/down button to scroll to the next function and value to be assigned, and assign the desired buttons. Repeat this procedure for each function and value to be assigned. 3. After assigning all button functions, press Save to save the button function information.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System • The first mode to be displayed is the current mode. • When programming from the front panel, exit time cannot be adjusted or displayed. If exit time has not been changed with iLux Designer or SIMPL Windows the default is 30 minutes. Scenes to be recalled also cannot be changed from the front panel.
iLux Integrated Lighting System • Crestron CLS/CLSI-C6 & CLS/CLSI-C6M All shade controllers of a given type are assigned to a single shade group. Use the “AS” option to change them. CAUTION: If there are SSC shade controllers on the network that do not have a functional shade connected to channel 1, shade control may not operate properly. Therefore, any SSC shade controllers without any shades attached should be removed from the network before running auto-discover.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System NOTE: Crestron drapery track controllers are also configured during the “Assign Shade Groups” process. Drapery track controller setup and functionality is identical to the setup of shades.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Photocell Test (Ph) This setup option is used to test photocell output. NOTE: Auto-discovery must be performed before the CLS-C6 recognizes a GLS-LOL photocell. The photocell must also be installed and wired to a GLS-SIM or C2N-CBD-P keypad. To test photocell output, see below: • Enter Setup mode and scroll to the “Ph” option (using the and buttons). Press and hold either the top or bottom portion of the raise/lower button.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System • Use the rocker buttons below each load to adjust each individual sensitivity level. Pressing the right half of the rocker button lowers the sensitivity, increasing light output level. Pressing the left half of the rocker button raises sensitivity, decreasing light output level. The 2-digit display indicates the current photocell level and the selected sensitivity. Light levels adjust automatically when the photocell reading changes.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Photocell Response Time (Pr) This setup option is used to adjust the lights’ response time to a change in the photocell reading. Valid values are 10 seconds, 30 seconds, 1 minute, 2 minutes, and 5 minutes. The default value is 1 minute. To adjust the response time of the photocell, see below: • Enter Setup mode and scroll to the “Pr” option (using the and buttons). Press either the top or bottom portion of the raise/lower button.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System NOTE: Only one CLS-C6 can be configured at a time. If there are multiple CLS-C6 units in a system, each one must be individually configured. Below are minimum software versions required to use the iLux Designer program: iLux Designer version 1.02.05 or later Crestron Toolbox version 1.01.11 or later Crestron Engraver version 2.5.0 or later* Crestron Database version 17.3.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M CLS-C6 The "CLS-C6" screen allows entry of the manual ramp rate used by the CLS-C6 when manually raising/lowering light levels, defines the functionality of the six function buttons, defines the behavior of the up/down button, specifies if scene raise/lower is enabled, and defines the entry action, the exit action, and motion sensor timeout when the motion sensor function is enabled.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System IR Reception 1. At the “iLux>” prompt, type IR and press Return to display the current setting. The system displays the following: IR reception is enabled (or disabled) iLux> 2. To disable IR reception, type IR disable and press Return. The system displays the following: IR reception is disabled iLux> 3. To enable IR reception, type IR enable and press Return.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M micro-perforated to make it easy to separate the desired label from the sheet. Carefully fold the sheet along the perforations to snap them apart. To replace the label on the unit, follow the procedure below: 1. Remove the front panel assembly by carefully pulling out and up from the bottom edge. 2. Carefully pull the label cover from the top edge at each side of the unit. Refer to the following illustration. 3.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (or device).
iLux Integrated Lighting System Indirect Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Indirect Communication Serial, Control System N LA or USB CLS-C6 Cresnet ITY AC AC RSW CO R ET H TE RN M PU PW QU IR TIV ITY AC TIV E -R W- PC Running Crestron Toolbox CLS-C6 connects to control system via Cresnet: 1. Click Tools | System Info. 2. Click the 3. For Connection Type, select Cresnet ID. In the Through drop-down menu, select the control system. 4. Click OK.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Operation The CLS-C6 always operates in one of four modes. Setup mode is used to redefine many of the CLS-C6 settings. Details regarding Setup mode are given in “Setup Mode” on page 13. The following sections provide detailed descriptions of Standard mode, Lights mode, and Shades mode.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Button Types The six function buttons can be programmed in Setup mode to be one of the following types. Using the iLux Designer software, other button functions may be specified. Refer to “Configuring With iLux Designer” on page 24 for details. • Recall-scene (specify scene number Off, On, 1–15). Refer to “Recall-Scene Buttons” below. • Toggle-scene (specify scene number On, 1–15). Refer to “Toggle-Scene Buttons” on page 33.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System ⇒ Any time all six lighting loads are off, all seven of these LEDs glow at a low intensity (to allow finding the CLS-C6 unit in the dark). Toggle-Scene Buttons • Used to alternately recall a scene or turn scene lights off (i.e., have the specified lighting loads go to off, in the specified time). • The toggle scene function should not be assigned to any scene that includes shades.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M IR Receiver Functions can also be triggered through the built-in RC5 IR receiver using the optional CLS-IRHT8 remote or a third-party remote. Refer to “Appendix G: RC5 Code Expansion” on page 84 for details. Occupancy Sensing Occupancy sensing utilizing the built-in sensors (CLS-C6) may have specific actions specified for entry and exit. Either or both of these may be disabled.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System While in Override mode, all Cresnet commands (whether sent by a control processor or by a master iLux to a slave) are ignored except for load level commands, which cause the new final value to be stored and thus recalled when the unit exits Override mode. Override mode levels take precedence over any limits set by Load Shed mode.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M • Unit 2 (Cresnet ID 0xC6): Defeat Occ Sensors/lockout front panel controls • Unit 3 (Cresnet ID 0xC7): Recall scenes 14/15 • Unit 4 (Cresnet ID 0xC8): Override mode/load shed For these units, DIP switches 0, 1, 2, and 3 determine whether the inputs are normally open, normally closed, active high, or active low. In order for the DIN-IO8 to be compatible with any model of BMS, one Cresnet ID treats the inputs as normally open.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System To exit Lights mode, press the Lights button again (or press Cancel) and the LED goes off. The unit returns to Standard mode. (Also, if no adjustments are made within 1 minute, the unit reverts to Standard mode.) Pressing the Shades button automatically exits Lights mode and enters Shades mode. Shades Mode Shades mode allows manual control any of the six shade groups. To enter Shades mode, raise the cover and press the Shades button.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M they affect the group (or groups) being adjusted, the manual adjustment of that shade group terminates and the new command takes precedence. To manually adjust this channel after that, release and re-press the button. The unit remains in Shades mode. To exit Shades mode, press the Shades button again (or press the Cancel button); the LED extinguishes and the unit returns to Standard mode.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CLS-C6 Troubleshooting TROUBLE Device does not function. POSSIBLE CAUSE(S) CORRECTIVE ACTION Unit is not receiving line power. Verify that the unit is properly connected to the power line and that the circuit breaker is closed.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M chained on the run, the Cresnet power usage of each network unit to be daisy chained must be added together to determine the Cresnet power usage of the entire chain. If the unit is run from a Crestron system power supply network port, the Cresnet power usage of that unit is the Cresnet power usage of the entire run.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Future Updates As Crestron improves functions, adds new features, and extends the capabilities of the CLS-C6, CLS-C6M, CLSI-C6, and CLSI-C6M, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron Web site periodically for manual update availability and its relevance.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Appendix A: Supported Devices The CLS-C6 local devices network supports up to 16 remote devices consisting of keypads, shade controllers, touch screens, and additional CLS-C6 units. Keypads Up to 16 keypads can be added on the local devices network. The following table lists default button functions for the keypad types currently supported. These settings can be changed using the front panel Setup mode or via iLux Designer.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Supported Keypads (Continued) KEYPAD TYPE CNX-B12 / C2N-DB12 BUTTON LAYOUT 1 2 3 4 5 6 7 8 9 10 11 12 C2N-CBD / C2N-CBF C2N-CBD-P / C2N-CBD-E / C2N-CBF-P 1 2 3 4 5 6 On Scene 1 Scene 2 Scene 3 Off C2NI-CB / INETI-CB Operations Guide – DOC.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Shade Controllers A maximum of 16 shade controllers can be added to the local devices network. The following shade controllers are currently supported (all sold separately): • C2N-SSC-2* • C2N-SDC • C2N-SDC-DC • CSM-QMT50-DCCN • CSC-DCCN • CSC-ACCN • CSC-DRPCN NOTE: The two channels on these shade controllers are labeled 1 and 2. SIMPL Windows cannot address the individual shade controllers.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System The iLux Designer help file includes a table indicating all the reserved joins supported by the touch screens. NOTE: These are not the standard reserved joins, but are the join numbers understood by the CLS-C6 for performing various actions. Joins Digital Command Joins External functions and their feedbacks are only supported by the master iLux. The slave CLS-C6(s) does not support external functions.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Digital Command Joins (from Touch Screen to CLS-C6) (Continued) JOIN DESCRIPTION 351 Save Edit Scene 352 Cancel Scene Programming 353-358 Remove load 1–6 from Edit Scene 359-364 Remove shade group 1–6 from Edit Scene 365 Lock Edit Scene 366 Unlock Edit Scene 367 Fade time up for Edit Scene 368 Fade time down for Edit Scene 370 Enable occupancy reporting 374 Enable entry scene 375 Disable entry scene 378 Enable ex
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Digital Command Joins (from Touch Screen to CLS-C6) (Continued) JOIN DESCRIPTION 526 Photocell sensitivity level down light zone 3 527 Photocell sensitivity level down light zone 4 528 Photocell sensitivity level down light zone 5 529 Photocell sensitivity level down light zone 6 530 Photocell dim min level up light zone 1 531 Photocell dim min level up light zone 2 532 Photocell dim min level up light zone 3 533 Photoce
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Digital Feedback Joins (from CLS-C6 to Touch Screen) (Continued) JOIN DESCRIPTION 6142 Load 6 is on 6144–6149 Load 1–6 is set to be non-dim 6150/6151/6152 Shade group 1 moving/last dir. Open/last dir. Close 6160/6161/6162 Shade group 2 moving/last dir. Open/last dir. Close 6170/6171/6172 Shade group 3 moving/last dir. Open/last dir. Close 6180/6181/6182 Shade group 4 moving/last dir. Open/last dir.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Digital Feedback Joins (from CLS-C6 to Touch Screen) (Continued) JOIN 6400–6799 DESCRIPTION Same as joins 6000–6355 but from Slave 1 --> touch screen 6800–7199 Same as joins 6000–6355 but from Slave 2 --> touch screen 7200–7599 Same as joins 6000–6355 but from Slave 3 --> touch screen 7600–7999 Same as joins 6000–6355 but from Slave 4 --> touch screen 8000–8399 Same as joins 6000–6355 but from Slave 5 --> touch screen 8400–8799
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Analog Feedback Joins (from CLS-C6 to Touch Screen) (Continued) JOIN DESCRIPTION 100–119, 400–419 Same as joins 20–39, 300–339 for slave 4 100–119, 400–419 Same as joins 20–39, 300–339 for slave 4 120–139, 420–439 Same as joins 20–39, 300–339 for slave 5 140–159, 440–459 Same as joins 20–39, 300–339 for slave 6 160–179, 460–479 Same as joins 20–39, 300–339 for slave 7 180–199, 480–499 Same as joins 20–39, 300–339 for slave 8
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Bidirectional Serial Joins Bidirectional Serial Joins (to/from CLS-C6 and Touch Screen) JOIN Operations Guide – DOC.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Appendix B: Console Commands Console commands are available through the Crestron Toolbox program. 1. Select Text Console from the Tools menu. 2. At the prompt, enter HELP ALL and press Return.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System GETCONFIG Description: Use this command to get project file information from the CLS-C6. Help Menu(s): File Syntax: GETCONFIG PROJECT Parameters: PROJECT to get the project file from iLux GREENLEDLEVEL Description: Use this command to display or set the green LED level on the CLS-C6. Refer to “LED Brightness” on page 27 for details. Help Menu(s): Device Syntax: GREENLEDLEVEL [0…100] set the green LED’s brightness to level [0.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M MOTIONSENSORLEVEL Description: Use this command to display and change the internal motion sensor sensitivity level.* Help Menu(s): Device Syntax: MOTIONSENSORLEVEL Parameters: Higher values make motion sensor less sensitive. Default is 78; valid range is [0…255] PROJECTINFO Description: Use this command to display the project file name, the date and time it was compiled, version and change flags.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System SYSTEM* Description: Use this command to load firmware to the CLS-C6. Help Menu(s): File Syntax: SYSTEM Parameters: None UPLOAD* Description: Use this command to load firmware to the slave device on the local network. Help Menu(s): File Syntax: UPLOAD [ID] FIRMWARE Parameters: [03…FE] FIRMWARE is the only valid value for this parameter VERSION Description: Use this command to display the firmware version number.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Appendix C: RS-232 Commands Connect the third party controller to the serial port of the C2N-IO. Connect the C2N-IO to the CLS-C6s Local Devices – G Z Y 24. ASCII commands received by the serial converter module are sent to the CLS-C6 slave Cresnet port. The CLS-C6 Cresnet serial packets are forwarded as ASCII strings to the third party controllers. Only one C2N-IO device is allowed on the local Cresnet network.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Serial Command String Format to Third Party Controllers. ILUX CONTROLLER COMMAND PAR1…X Refer to the “iLux Controller Code Table” below for a list of available options. Refer to the “RS-232 Command Table” on the following page which provides a description of available commands and the required syntax. A list of available variables that can be entered into the command. The brackets should be removed from the command. [Par1] [……..
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M RS-232 Command Table COMMAND DESCRIPTION SYNTAX REPLY CATEGORY Control Echo Cmd [ILUX] ECHO ON|OFF Light zone Control Set Light zone Level [ILUX] LZ [X|ALL] LVL [LEVEL] [FADETIME] Light zone Control Get Light zone Level [ILUX] LZ [X|ALL] LVL ? Light zone Control Raise Light zone [ILUX] LZ [X|ALL] UP [FADERATE] Light zone Control Lower Light zone [ILUX] LZ [X|ALL] DN [FADERATE] Light zone Control Stop Light zone [ILUX
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System RS-232 Command Table (Continued) COMMAND DESCRIPTION SYNTAX REPLY CATEGORY Scene Control Stop scene raise/lower [ILUX] SC [XX] STOP Scene Control Toggle scene [ILUX] SC [XX] TOG Scene Control Turn off lights in scene [ILUX] SC [XX] OFF Scene Control Read Scene state Active [ILUX] SC [XX|ALL] STATE ? Scene programming Scene quick save [ILUX] SC [XX] SAVE Scene programming Read Scene light level [ILUX] SC [XX] LZLVL ?
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M RS-232 Command Table (Continued) COMMAND DESCRIPTION SYNTAX REPLY CATEGORY Occupancy Read occupancy state [ILUX] OC ? [ILUX] OC [STATE] Photocell Read Photocell active state [ILUX] PH [X|ALL] ACTIVE ? [ILUX] PH [X] ACTIVE [STATE1][…][STATE6] Version Read version number [ILUX] VER ? [ILUX] VER [ID STRING] NOTE: Command and response parameters are separated by blank spaces.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System ALL = ALL Light zones Reply packet: [ILUX] LZ [X|ALL] LVL [LEVEL1] [….] [LEVEL6] LEVEL x = 0–100 (for light zone 1 through 6) Light Zone Lower or Raise Command The specified lighting load (or all loads) ramps up or down at the specified rate. The FADERATE is specified as the time it takes to raise or lower the full range (from full off to full on or full on to full off).
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M ALL = All light zones Reply packet: [ILUX] LZ [XX|ALL] MIN [LIMIT1] [….] [LIMIT6] LIMITx = 0–100 (for light zone 1 through 6) Light Zone Upper Limit Command The following command is used to get light zone maximum limit. This command is not supported for slave CLS-C6 controllers: Syntax: M LZ [X|ALL] MAX ? X=1–6 light zone Reply packet: M LZ [X|ALL] [MAX] [LIMIT1] [….
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System [ILUX] LZ ALL NAME [LABEL1], […], [LABEL6] LABELx = Light zone names separated by comma Shade Group Commands Shade Group Operation Commands Shade Group Position Command The following command is used to set shade group position: Syntax: [ILUX] SZ [X|ALL] POS [LEVEL] X = 1–6 Shade group ALL = All Shade groups LEVEL = 0–100 Shade Group Position Query Command The following command is used to get shade group position.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M X=1–6 Shade group Reply packet: [ILUX] SZ [X] NAME [LABEL] LABEL = Shade zone name [ILUX] SZ ALL NAME [LABEL1], […], [LABEL6] LABELx = Shade group names separated by comma Shade Type Query Command The following command is used to query shade type. Command is not supported for slave CLS-C6 devices.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Scene Toggle Command The following command is used to toggle scene lights. Command is not supported for Off scene: Syntax: M SC [XX] [TOG] XX = ON, 1–15 Scenes Scene Turn Off Lights Command The following command is used to turn off scene lights: Syntax: [ILUX] SC [XX] OFF XX = ON, 1–15 Scenes Scene State Query Command The following command is used to read scene states. This command is not supported for slave CLS-C6 devices.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Scene Query Shade Group Level Command This command is used to read shade level in scenes. This command is not supported for slave CLS-C6 devices. Syntax: M SC [XX] SZLVL ? XX = OFF, ON, 1–15 (Scenes) Reply packet: M SC [XX] SZLVL [LEVEL1] [….] [LEVEL6] LEVELx = 0–100 for shade zone1 through shade zone6 Scene Light Add/Remove Mask Command This command is used to remove or add light zones to scenes.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Scene Name Query Command The following command is used to query scene name: Syntax: [ILUX] SC [XX] NAME ? XX = OFF, ON, 1–15 Scenes Reply packet: [ILUX] SC [XX] NAME [LABEL] LABEL=Scene name Room Combining Commands Combine Rooms This command is used to combine room controllers. This command is not supported for slave CLS-C6 devices.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Override Status Command The following command reads the override status.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Photocell Commands Photocell Operation Commands Photocell Enable Command The following command is used to query photocell active state: Syntax: [ILUX] PH [X|ALL] ACTIVE ? X = 16 light zone Reply packet: [ILUX] PH [X] ACTIVE [STATE] STATE = ON/OFF [ILUX] PH [ALL] ACTIVE [STATE1][….][STATE6] Version Command The following command is used to query version string. This command is not supported for slave CLS-C6 devices.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Appendix D: Factory Default Values Factory Default Values ITEM All lighting load types. All Low-End limits All High-End limits Function buttons Up/Down button Occupancy sensing DEFAULT VALUE Incandescent 0% 100% Recall scenes 1–6 Lights (Last Scene Master).
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Factory Default Values (Continued) ITEM Green LED brightness level White LED brightness level White LED glow level DEFAULT VALUE 63 70 7 The Cresnet ID (default=1F) in the configuration memory is not be affected by the Fd function (unless configuration data is corrupt). Operations Guide – DOC.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Appendix E: Button Functions Following is a list of button functions, in table format, one function per table. Each table lists “Behavior,” “LED action,” “Applies to”, “Rocker behavior,” and “Notes.” Some topics may not apply to certain button types; this is defined in the “Applies to” row.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME Behavior TURN OFF SCENE LIGHTS (ON, 1–15) Same as Recall Scene button, except a) All lights affected by the scene go to off level. b) Shades are not affected. Note that the list of unaffected lighting loads and the fade time are the same as for the Recall Scene function. LED Flash while lights are fading, off when fade is done.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME LOWER LIGHTING LOAD (1–6) Behavior Specified lighting load lower as long as button is held. It stops when button is released. Rate is the global ramp rate. If loads hit the low-end limit, the bar graph continues to go down, but lights stays at low-end limit level until reach OFF—at which point they turn off.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME Behavior MASTER LOWER LIGHTING LOADS (LAST SCENE, ALL LIGHTS, ON SCENE, SCENES 1–15) Same as Lower Lighting Load, except acts on all dimmable Lighting Loads affected by the specified scene. All lights ramp at the same rate. Non-dim loads are not affected. Shades are not affected. LED On while button is pressed Applies To Standard Rocker, Shifted Rocker, Remote Button Rocker Behavior Left, right, and center all perform the same function.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME OPEN SHADES FULL (ALL, GROUP 1–6) Behavior Sends the specified shades to Full Open position. LED On while button is pressed Applies To Remote Button Rocker Behavior N/A Notes Shade commands with “All” parameter only affect all the shade groups connected to the given CLS-C6 module. They do not pass from one CLS-C6 module to another (either when directly connected or when linked through a Cresnet system).
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME Behavior OPEN SHADES MOMENTARY (ALL, GROUP 1–6) Specified shades move toward the Open position for as long as the button is pressed. Movement stops when button is released. LED On while button is pressed Applies To Remote Button Rocker Behavior N/A Notes Shade commands with “All” parameter only affect all the shade groups connected to the given CLS-C6 module.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME JOG SHADES CLOSED (ALL, GROUP 1–6) Behavior Specified shades move toward the Closed position for the specified jog time, and then stop. LED On while button is pressed Applies To Remote Button Rocker Behavior N/A Notes Jog time defaults to 0.05 sec. Other values can be set in iLux Designer. Shade commands with “All” parameter only affects all the shade groups connected to the given CLS-C6 module.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME Behavior CLOSE MOMENTARY/CLOSE FULL (ALL, GROUP 1–6) Same as “Open Momentary/Open Full Shade Group 1–6” except Close. LED On while button is pressed Applies To Remote Button Rocker Behavior N/A Notes Same as “Open Momentary/Open Full Shade Group 1–6.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M FUNCTION NAME DUAL EXTERNAL FUNCTION (1/2 …31/32) Behavior Activates the corresponding “press” digital signal (press1– press32 on the External Functions slot) on the Cresnet system connected to the CONTROL SYSTEM port. Signal remains high for as long as the button is pressed. The left button corresponds to the lower number. The right button corresponds to the higher number.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Appendix F: Room Combining The CLS-C6 supports a room combining concept, whereby two adjacent rooms are considered separate when a partition is closed, and combined when the partition is open. Refer to the figures on the following page for examples of room combining. In a system that can include a master CLS-C6 and up to eight slave CLS-C6 units, there are 36 possible partitions between rooms.
iLux Integrated Lighting System • Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Override is shared for all combined/uncombined rooms (when triggered from master CLS-C6) A CLS-C6 that is combined with another CLS-C6 that is, in turn, combined with a third shall be considered combined with that third CLS-C6.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System Room Combining Possible Partition Combinations Operations Guide – DOC.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Appendix G: RC5 Code Expansion RC5 codes are now assigned for all CLS-C6 functions that can be accessed via SIMPL Windows. Refer to the following table.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System RC5 Codes Function Table (Continued) CODE Key 33 Operations Guide – DOC.
iLux Integrated Lighting System Crestron CLS/CLSI-C6 & CLS/CLSI-C6M Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from Crestron. To obtain warranty service for Crestron products, contact an authorized Crestron dealer. Only authorized Crestron dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M iLux Integrated Lighting System This page is intentionally left blank. Operations Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 6347G (2012613) 09.13 Specifications subject to change without notice.