Specifications

Crestron CLW-DIM1/4RF, -DIMS1/4RF, -SLVD1RF infiNET™ Dimmers
Setup Complete
11. Click Close to close the window once all devices have been identified. All
of the identified devices in the Network Device tree will be indicated with
the
icon as shown in the following diagram.
Network Device Tree with Devices Set Up with SMW Program Tree
Manually Set MNET ID
in Crestron Toolbox
The following method permits you to change the MNET ID of any infiNET device
on the infiNET network through the “Network Device Tree” window.
This method does not change the MNET ID as assigned in SIMPL Windows. For
information on setting the MNET ID in SIMPL Windows, refer to “Programming
with SIMPL Windows” on page 23. If MNET IDs have already been assigned in a
SIMPL Windows program, use the Touch Settable ID method described on page 13
to change the MNET ID to match the MNET ID specified in the SIMPL Windows
program.
NOTE: You may also use D3 Pro or SystemBuilder to perform MNET ID setup.
Refer to the respective help file for more information.
1. Open Crestron Toolbox and establish communications with the control
system (refer to “Establishing Communication” on page 26).
2. Use the Network Device Tree and connect to the control system to verify
that the gateway is connected to the control system and that all infiNET
devices are acquired on the gateway. infiNET devices with MNET ID 01
will be shown with a
icon as shown in the following diagram.