Specifications

Crestron TPMC-12 Isys i/O
®
Tilt Touchpanel Media Center
Standby Details
The Standby function turns off the backlight when the touchpanel is inactive for a
specified time. Use the Up and Down buttons to set the Standby from 0 through 120
minutes, where 0 disables the timeout. Touch the screen to reactivate the touchpanel
from standby mode. When the touchpanel is reactivated, the last screen to be
displayed reappears.
NOTE: The hard buttons will still function when the touchpanel is in standby mode
but will not cause it to awaken from standby. You must touch the screen to reactivate
the touchpanel.
Hard Button Backlight Details
The Hard Button Backlight can be varied from 0 to 100. To increase the brightness,
touch Up. To decrease the brightness, touch Down.
Misc. Controls Details
The Misc. Controls section of the setup menu contains the Diagnostics and
Keyboard buttons.
Diagnostics
Touch Diagnostic to display the firmware version number, see Installed Packs and
to reset the end user license from the “Diagnostics” window.
“Diagnostics” Window
Reset CTP Port resets the default value of the CTP port to 41795, for terminal
connection using Crestron Toolbox.
To configure the appearance of popup messages, touch Configure Messages. The
“Message Popup Configuration” window will open.
Operations Guide – DOC. 6675A Isys i/O
®
Tilt Touchpanel Media Center: TPMC-12 37