User Guide
Professional Audio Distribution Processor Crestron CNX-BIPAD8
24 • Professional Audio Distribution Processor: CNX-BIPAD8 Operations Guide - DOC. 8160A
“Open” Window
4. Browse to the desired upg file and click Open to begin the transfer.
Problem Solving
Troubleshooting
The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CNX-BIPAD8 Troubleshooting
TROUBLE
POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
CNX-BIPAD8 does
not function.
Incorrect power
supply.
Use a Crestron power supply.
Power LED does
not Illuminate
CNX-BIPAD8 is not
receiving power.
Verify that cable plugged into NET port is
secure. Ensure sufficient NET power to support
all NET devices.
NET LED does not
illuminate
Loose network
connection.
Verify that cable plugged into NET port is
secure.
Improper NET ID. Verify that CNX-BIPAD8 NET ID matches NET
ID software program. Refer to "Identity Code" on
page 9 of this operations guide.
ROOM 1-8 LEDs
do not illuminate.
Improper
programming.
Confirm signal names and programmming logic
so that LEDs respond when functions are
activated.
Audio not balanced
or poor sound
quality.
Room not set up. Room must be set up from a touch panel to
adjust bass, treble, balance, etc.
Hum on audio. Grounding problem. Either connect or remove chassis ground wire.