Specifications
Crestron DMPS-100/200/300-C/300-C-AEC DigitalMedia Presentation System
Operations Guide – DOC. 7219E DigitalMedia Presentation Systems: DMPS-100/200/300-C/300-C-AEC
•
35
Hardware Connections for the DMPS-300-C/300-C-AEC
NOTE: Tie all source and device grounds to the ground terminal. Ensure the unit is
properly grounded by connecting the chassis ground lug to an earth ground (building
steel).
NOTE: To prevent overheating, do not operate this product in an area that exceeds
the environmental temperature range listed in the table of specifications.
NOTE: For optimum performance, Crestron requires using DM-CBL DigitalMedia
cable, available from Crestron.
NOTE: Minimum allowed length for DM-CBL DigitalMedia cable is 15 feet (~4.6
meters).
Four balanced/unbalanced audio inputs are provided on the DMPS-100-C, five such
inputs are available on all other DMPS models. These inputs utilize 5-pin terminal
block connectors. For connection details, refer to the following table and diagrams.
Audio Connections
SIGNAL
NAME
BALANCED
AUDIO INPUT
BALANCED
AUDIO
OUTPUT
UNBALANCED
AUDIO INPUT
UNBALANCED
AUDIO OUTPUT
+ L + L + L + In L + Out
- L - L -
L – signal return,
jumper to GND
Open
G Shield/ground Shield/ground Ground Common Ground
+ R + R + R + In R + Out
- R - R -
R – signal return
jumper to GND
Open