Crestron Green Light™ DIN-IO8 DIN Rail Versiport Module Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Crestron DIN-IO8 DIN Rail Versiport Module Contents Crestron Green Light™ DIN Rail Versiport Module: DIN-IO8 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Applications.................................................................................................................
Crestron DIN-IO8 DIN Rail Versiport Module Crestron Green Light™ DIN Rail Versiport Module: DIN-IO8 Introduction The DIN-IO8 is a DIN rail-mounted automation control module that provides eight Versiport I/O ports for interfacing with a wide range of third-party devices and systems. Each “Versiport” can be configured via software to function as a digital or analog sensing input, or as a digital trigger output.
DIN Rail Versiport Module Crestron DIN-IO8 digital output, the Versiport provides a logic level closure signal to trigger control and alarm inputs on a variety of external devices. DIN Rail Installation The DIN-IO8 is designed to snap onto a standard DIN rail for installation in a wall mount enclosure or mounted on a wall panel. Wiring connections are made using detachable screw terminals positioned along the top and bottom, clearly accessible from the front for easy installation and servicing.
Crestron DIN-IO8 DIN Rail Versiport Module Applications The following diagram shows a DIN-IO8 in a commercial application. DIN-IO8 in a Commercial Application Operations & Installation Guide – DOC.
DIN Rail Versiport Module Crestron DIN-IO8 Specifications Specifications for the DIN-IO8 are listed in the following table. DIN-IO8 Specifications SPECIFICATION DETAILS Power Requirements Cresnet Power Usage 1.5 Watts (0.06 Amps @ 24 Volts DC) 84 Version 4. 000.
Crestron DIN-IO8 DIN Rail Versiport Module DIN-IO8 Specifications (Continued) SPECIFICATION Available Accessories DIN-BLOCK DIN-HUB DIN-PWS50 DETAILS DIN Rail Cresnet Distribution Block DIN Rail Cresnet Distribution Hub DIN Rail 50 Watt Cresnet Power Supply 1. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following these footnotes. 2. Crestron 2-Series control systems include the AV2 and PRO2.
DIN Rail Versiport Module Crestron DIN-IO8 DIN-IO8 Overall Dimensions 58 mm (2.28 in) 106 mm (4.17 in) 1 94.2 mm (3.71 in) 90 mm (3.54 in) 2 3 4 5 6 7 59.5 mm (2.34 in) Connectors, Controls & Indicators # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 1 I/O 1-8 and LEDs (2) 5-pin 3.5 mm detachable terminal blocks comprising (8) digital input/output or analog input ports (referenced to GND); Max Wire Size: 1.
Crestron DIN-IO8 DIN Rail Versiport Module Connectors, Controls & Indicators (Continued) # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 1 I/O 1-8 and LEDs (continued) 2 NET ID DISPLAY & CONTROL Analog Input: Rating: 0-10 Volts DC, protected to 24 Volts DC maximum Input Impedance: 20k ohms Digital Output: 250 mA sink from maximum 24 Volts DC, catch diodes for use with “real world” loads Programmable 5 Volts, 2k ohms pull-up resistor per input (8) Red LEDs, indicate status of each respective I/O V
DIN Rail Versiport Module Crestron DIN-IO8 Connectors, Controls & Indicators (Continued) * # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 4 SETUP (LED and button) 5 PWR 6 RESET 7 NET (1) Red LED and (1) recessed miniature pushbutton for enabling setup mode and touch-settable ID (1) Green LED, illuminates when DC power is applied to the NET port (1) Recessed miniature pushbutton, resets internal processor (1) Yellow LED, indicates communication with the control processor Interface connector
Crestron DIN-IO8 DIN Rail Versiport Module Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United States. Formal approval is pending. As of the date of manufacture, the DIN-IO8 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
DIN Rail Versiport Module Crestron DIN-IO8 Setup Network Wiring When wiring the Cresnet network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet-HP wire cannot be used. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
Crestron DIN-IO8 DIN Rail Versiport Module • When the desired Net ID is displayed, press the SETUP button to exit the Setup mode. The SETUP LED extinguishes. NOTE: If an invalid Net ID is set (00, 02, FF), “Er” will be displayed on the NET ID display. The DIN-IO8 reverts to the previously set Net ID. NOTE: The DIN-IO8 will leave the Setup mode after 10 seconds of inactivity. The DIN-IO8 will revert to the previously set Net ID.
DIN Rail Versiport Module Crestron DIN-IO8 The DIN-IO8 is designed for installation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-IO8 DIN-IO8 TOP DIN RAIL (NOT SUPPLIED) DIN RAIL RELEASE 1. Place the top of the DIN-IO8’s rail mount over the top of the DIN rail. 2. Tilt the bottom of the DIN-IO8 toward the DIN rail until it snaps into place.
Crestron DIN-IO8 DIN Rail Versiport Module Hardware Hookup Connect the Device Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 10 before attaching the 4-position terminal block connector. Apply power after all connections have been made. WARNING: Prior to connecting the device, turn off power at the circuit breaker. Failure to do so may result in serious personal injury or damage to the device.
DIN Rail Versiport Module Crestron DIN-IO8 Hardware Connections for the DIN-IO8 I/O: TO / FROM DEVICES NET: TO CONTROL SYSTEM AND OTHER CRESNET DEVICES 14 • DIN Rail Versiport Module: DIN-IO8 Operations & Installation Guide – DOC.
Crestron DIN-IO8 Versiport Connections DIN Rail Versiport Module Depending on the application, the DIN-IO8’s Versiports can be wired multiple ways. Refer to the following diagrams when wiring a Versiport. WARNING: Incorrect wiring may damage the DIN-IO8. NOTE: The settings for input/output and the pull-up resistor are specified in the control system program. For more information, refer to the SIMPL Windows help file.
DIN Rail Versiport Module Crestron DIN-IO8 Versiport Wiring Diagrams—Analog Input Function Reading a voltage from an analog source Reading resistance of a potentiometer 10V DC I/O Setup: Analog Input I/O Setup: Analog Input Pull-up Resistor: Disabled Pull-up Resistor : Enabled Versiport Wiring Diagrams—Digital Output Function Driving a relay coil 24V DC Max. I/O Setup: Digital Output Pull-up Resistor: Disabled 16 • DIN Rail Versiport Module: DIN-IO8 Operations & Installation Guide – DOC.
Crestron DIN-IO8 DIN Rail Versiport Module Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com. First-time users will need to establish a user account.
DIN Rail Versiport Module Crestron DIN-IO8 Programming with D3 Pro Crestron’s D3 Pro lighting software provides all the tools necessary to create a complete Crestron lighting system for residential applications. The lighting system includes the control system logic program, touchpanel projects and keypad programming, documentation and realtime lighting adjustment capabilities.
Crestron DIN-IO8 DIN Rail Versiport Module Locating the DIN-IO8 in the Device Library • The system tree of the control system displays the device in the appropriate slot with a default Net ID as shown in the following illustration. C2Net Device, Slot 5 • Additional DIN-IO8 devices are assigned different Net ID numbers as they are added. Operations & Installation Guide – DOC.
DIN Rail Versiport Module Crestron DIN-IO8 • If necessary, double click a device to open the “Device Settings” window and change the Net ID as shown in the following figure. “DIN-IO8 Device Settings” Window • The ID code specified in the SIMPL Windows program must match the Net ID of each unit. Refer to “Identity Code” on page 10. Program Manager Program Manager is the view where programmers “program” a Crestron control system by assigning signals to symbols.
Crestron DIN-IO8 DIN Rail Versiport Module Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
DIN Rail Versiport Module Crestron DIN-IO8 Programs and Firmware Program or firmware files may be distributed from programmers to installers or from Crestron to dealers. Firmware upgrades are available from the Crestron website as new features are developed after product releases. One has the option to upload programs via the programming software or to upload and upgrade via the Crestron Toolbox.
Crestron DIN-IO8 DIN Rail Versiport Module Operation Net ID Use the NET ID buttons to change the Net ID of the DIN-IO8. For more information on Net ID, refer to “Identity Code” on page 10. Reset To reboot the DIN-IO8, press the RESET button. The ports function as specified by the control system program. If the control system does not provide settings, the ports will be set to the previous settings. Operations & Installation Guide – DOC.
DIN Rail Versiport Module Crestron DIN-IO8 Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. DIN-IO8 Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Device does not function. Device is not communicating with the network. Use Crestron Toolbox to poll the network. Verify network connection to the device. Use a Crestron power source.
Crestron DIN-IO8 DIN Rail Versiport Module DIN-IO8 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) Input/Output port Incorrect pull-up not responding resistor setting. as expected. CORRECTIVE ACTION Verify pull-up resistor setting in SIMPL Windows program. Check Network Wiring Use the Right Wire Calculate Power In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used.
DIN Rail Versiport Module Crestron DIN-IO8 Cable Length Equation 40,000 L< RxP Where: L = Length of run (or chain) in feet 2 R = 6 Ohms (Crestron Certified Wire : 0.75 MM (18 AWG)) P = Cresnet power usage of entire run (or chain ) Make sure the cable length value is less than the value calculated on the right side of the equation. For example, a Cresnet run using 0.75mm2 (18 AWG) Crestron Certified Wire and drawing 20 watts should not have a length of run more than 101 meters (333 feet).
Crestron DIN-IO8 DIN Rail Versiport Module Further Inquiries If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to ask questions about Crestron products.
DIN Rail Versiport Module Crestron DIN-IO8 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron DIN-IO8 DIN Rail Versiport Module This page is intentionally left blank. Operations & Installation Guide – DOC.
DIN Rail Versiport Module Crestron DIN-IO8 This page is intentionally left blank. 30 • DIN Rail Versiport Module: DIN-IO8 Operations & Installation Guide – DOC.
Crestron DIN-IO8 DIN Rail Versiport Module This page is intentionally left blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6664A (2020746) 05.08 Specifications subject to change without notice.