Crestron Green Light™ DIN-AO8 DIN Rail Analog Output Module Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Crestron DIN-AO8 DIN Rail Analog Output Module Contents Crestron Green Light™ DIN Rail Analog Output Module: DIN-AO8 1 Introduction ............................................................................................................................... 1 Features and Functions ................................................................................................ 1 Applications................................................................................................................
Crestron DIN-AO8 DIN Rail Analog Output Module Crestron Green Light™ DIN Rail Analog Output Module: DIN-AO8 Introduction The DIN-AO8 is a DIN rail-mounted automation control module that provides eight analog output ports for interfacing with third-party lighting and heating/cooling systems*. * Care must be taken when using a control system to directly control HVAC elements, as opposed to using a dedicated HVAC thermostat or other controller.
DIN Rail Analog Output Module Crestron DIN-AO8 and other devices providing a 0-10V analog input. Ten-bit resolution ensures precision and smooth ramping between levels. DIN Rail Installation The DIN-AO8 is designed to snap onto a standard DIN rail for installation in a wall mount enclosure or mounted on a wall panel. Wiring connections are made using detachable screw terminals positioned along the top and bottom, clearly accessible from the front for easy installation and servicing.
Crestron DIN-AO8 DIN Rail Analog Output Module Applications The following diagram shows a DIN-AO8 in a commercial application. DIN-AO8 in a Commercial Application Operations & Installation Guide – DOC.
DIN Rail Analog Output Module Crestron DIN-AO8 Specifications Specifications for the DIN-AO8 are listed in the following table. DIN-AO8 Specifications SPECIFICATION Power Requirements Cresnet Power Usage Default NET ID Minimum 2-Series Control System Update File1, 2 Environmental Temperature Humidity Heat Dissipation Enclosure Dimensions Height Width Depth Weight Available Accessories DIN-BLOCK DIN-HUB DIN-PWS50 DETAILS 6 Watts (0.25 Amps @ 24 Volts DC) 88 Version 4.000.
Crestron DIN-AO8 DIN Rail Analog Output Module 1. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following these footnotes. 2. Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product Catalog for a complete list of 2-Series control systems. NOTE: Crestron software and any files on the website are for authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only.
DIN Rail Analog Output Module Crestron DIN-AO8 DIN-AO8 Overall Dimensions 58 mm (2.28 in) 106 mm (4.17 in) 1 94.2 mm (3.71 in) 90 mm (3.54 in) 2 7 3 8 4 5 6 59.5 mm (2.34 in) Connectors, Controls & Indicators # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 1 OUTPUTS 1-8 with LEDs and Buttons (4) 4-pin 3.
Crestron DIN-AO8 DIN Rail Analog Output Module Connectors, Controls & Indicators (Continued) # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 2 NET ID DISPLAY & CONTROL (2) 7-Segment green LED digits and (2) miniature pushbuttons for setting Net ID, displaying output levels, and indicating errors 3 NET 4 SETUP (LED and button) (2) 4-pin 3.5 mm detachable terminal blocks, paralleled Cresnet slave port Max Wire Size: 1.
DIN Rail Analog Output Module Crestron DIN-AO8 Connectors, Controls & Indicators (Continued) * # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 5 OVERRIDE with LEDs and Button 6 PWR 7 NET 8 RESET (2) 2-pin 3.5 mm detachable terminal blocks, paralleled Max Wire Size: 1.
Crestron DIN-AO8 DIN Rail Analog Output Module Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United States. Formal approval is pending. As of the date of manufacture, the DIN-AO8 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
DIN Rail Analog Output Module Crestron DIN-AO8 Setup Network Wiring When wiring the Cresnet network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet-HP wire cannot be used. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
Crestron DIN-AO8 DIN Rail Analog Output Module • When the desired Net ID is displayed, press the SETUP button to exit the Setup mode. The SETUP LED extinguishes. NOTE: If an invalid Net ID is set (00, 02, FF), “Er” will be displayed on the NET ID display. The DIN-AO8 reverts to the previously set Net ID. NOTE: The DIN-AO8 will leave the Setup mode after 10 seconds of inactivity. The DIN-AO8 will revert to the previously set Net ID.
DIN Rail Analog Output Module Crestron DIN-AO8 The DIN-AO8 is designed for installation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-AO8 DIN-AO8 TOP DIN RAIL (NOT SUPPLIED) DIN RAIL RELEASE 1. Place the top of the DIN-AO8’s rail mount over the top of the DIN rail. 2. Tilt the bottom of the DIN-AO8 toward the DIN rail until it snaps into place.
Crestron DIN-AO8 DIN Rail Analog Output Module Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 10 before attaching the 4-position terminal block connector. Apply power after all connections have been made. WARNING: Prior to connecting the device, turn off power at the circuit breaker. Failure to do so may result in serious personal injury or damage to the device.
DIN Rail Analog Output Module Crestron DIN-AO8 Hardware Connections for the DIN-AO8 14 • DIN Rail Analog Output Module: DIN-AO8 Operations & Installation Guide – DOC.
Crestron DIN-AO8 DIN Rail Analog Output Module Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com. First-time users will need to establish a user account.
DIN Rail Analog Output Module Crestron DIN-AO8 Programming with D3 Pro Crestron’s D3 Pro lighting software provides all the tools necessary to create a complete Crestron lighting system for residential applications. The lighting system includes the control system logic program, touchpanel projects and keypad programming, documentation and realtime lighting adjustment capabilities.
Crestron DIN-AO8 DIN Rail Analog Output Module Locating the DIN-AO8 in the Device Library • The system tree of the control system displays the device in the appropriate slot with a default Net ID as shown in the following illustration. C2Net Device, Slot 5 • Additional DIN-AO8 devices are assigned different Net ID numbers as they are added. Operations & Installation Guide – DOC.
DIN Rail Analog Output Module Crestron DIN-AO8 • If necessary, double click a device to open the “Device Settings” window and change the Net ID as shown in the following figure. “DIN-AO8 Device Settings” Window • The ID code specified in the SIMPL Windows program must match the Net ID of each unit. Refer to “Identity Code” on page 10. Program Manager Program Manager is the view where programmers “program” a Crestron control system by assigning signals to symbols.
Crestron DIN-AO8 DIN Rail Analog Output Module Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the control system (and/or device).
DIN Rail Analog Output Module Crestron DIN-AO8 Programs and Firmware Program or firmware files may be distributed from programmers to installers or from Crestron to dealers. Firmware upgrades are available from the Crestron website as new features are developed after product releases. One has the option to upload programs via the programming software or to upload and upgrade via the Crestron Toolbox.
Crestron DIN-AO8 DIN Rail Analog Output Module Operation Net ID Use the NET ID buttons to change the Net ID of the DIN-AO8. For more information on Net ID, refer to “Identity Code” on page 10. Manual Control The level of each of the analog outputs can be manually controlled from the front panel. To toggle the output between off (0V) and the programmed upper limit (10V), tap an output button.
DIN Rail Analog Output Module Save Override Levels Crestron DIN-AO8 The level of each output can be saved as an override setting which can be automatically recalled when the Override mode is enabled. NOTE: The control system program has a setting that can prevent locally saving the override level settings. If this setting is enabled, the display shows “Er” when trying to save the override level settings. For more information, refer to the SIMPL Windows help file.
Crestron DIN-AO8 DIN Rail Analog Output Module Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. DIN-AO8 Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Device does not function. Device is not communicating with the network. Use Crestron Toolbox to poll the network. Verify network connection to the device. Use a Crestron power source.
DIN Rail Analog Output Module Calculate Power Crestron DIN-AO8 CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. CAUTION: Provide sufficient power to the system. Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
Crestron DIN-AO8 DIN Rail Analog Output Module Apply solder only to the ends of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle. Insert the tinned connection into the Cresnet connector and tighten the retaining screw. Repeat the procedure for the other three conductors. Add Hubs Use of a Cresnet Hub/Repeater (DIN-HUB) is advised whenever the number of Cresnet devices on a network exceeds 20 or when the combined total length of Cresnet cable exceeds 914 meters (3000 feet).
DIN Rail Analog Output Module Crestron DIN-AO8 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron DIN-AO8 DIN Rail Analog Output Module This page is intentionally left blank. Operations & Installation Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6663A (2020745) 05.08 Specifications subject to change without notice.