User Guide
FlipTop Control Center with Cresnet
®
Crestron C2N-FTB
A C2N-FTB in Slot 9
NOTE: The first C2N-FTB in a system is preset with a Net ID of 1E when its
symbol is dragged into the upper pane of System Views. Additional units are
assigned different Net ID numbers as they are added.
Setting the Net ID in Device Settings
Double-click the C2N-FTB icon in the upper pane to open the “Device Settings”
window. This window displays C2N-FTB device information. The Net ID can
be changed in this window using the Net ID tab, as shown in the following
figure.
“Device Settings” Window
NOTE: This procedure sets the Net ID for the C2N-FTB in the program only. It
does not automatically set the Net ID for the C2N-FTB itself. SIMPL Windows
automatically changes Net ID values of a device added to a program if a
duplicate device or a device with the same Net ID already exists in the program.
Always ensure that the hardware and software settings of the Net ID match. For
Net ID hardware setting details, refer to “Identity Code” on page 8.
20 • FlipTop Control Center with Cresnet
®
: C2N-FTB Operations & Installation Guide - DOC. 6338