Crestron C2N-RTHS Remote Temperature/Humidity Sensor Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2005 Crestron Electronics, Inc.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor Contents Remote Temperature/Humidity Sensor: C2N-RTHS 1 Introduction......................................................................................1 Specifications.........................................................................2 Physical Description ..............................................................3 Industry Compliance..............................................................4 Network Wiring ...........................
Crestron C2N-RTHS Remote Temperature/Humidity Sensor Remote Temperature/Humidity Sensor: C2N-RTHS Introduction The C2N-RTHS is a network device remote temperature/humidity sensor. This product connects to the Cresnet system for reporting temperature and relative humidity to the processor.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS Specifications SPECIFICATION DETAILS Default ID Control System Update Files1, 2, 3 2-Series Control System CNMSX-AV/Pro Update File CNRACKX/-DP Update File CEN/CN-TVAV Update File Firmware Version Temperature Range 2B Humidity Range Power Dimensions Version 2.004.CUZ or later Version 5.12.63X.UPZ or later Version 5.12.63W.UPZ or later Version 5.12.63V.UPZ or later C2N-RTHS.V1.4.UPG -40º to 176ºF (-40º to 80ºC) 0.1ºF (0.1ºC) Output Resolution 1.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor Physical Description Refer to the following illustrations. The face of the sensor is 1.5 in (3.81 cm) in diameter, and has an LED and pinhole access for the TSID button. The sensor body is 2.0 in (5.64 cm) long, and mounts nearly flush to the wall. The C2N-RTHS remote sensor is contained in a cylindrical plastic body. It mounts in a one-inch diameter hole, exposing a 1.5 in (3.81 cm) diameter disk that protrudes approximately 0.2 inch (0.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS Side Views Industry Compliance As of the date of manufacture, the C2N-RTHS has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. NOTE: When installing network wiring, refer to the latest revision of the wiring diagram(s) appropriate for your specific system configuration, available from the Crestron website. NOTE: For larger networks (i.e.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation. Refer to the following table. Wire Gauge Values RESISTANCE WIRE GAUGE 4 6 10 15 13 8.7 16 18 20 22 Doubled CAT5 Tripled CAT5 NOTE: All Cresnet wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor, and the other twisted pair is the Y conductor and the Z conductor.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor 5. Route the Cresnet wires to the sensor. Use the four wire nuts included to connect the wires (red to red, white to white, blue to blue, and black to black). 6. Press fit the sensor into the hole; the clips on either side of the sensor hold it in place. NOTE: The face of the sensor may be painted or wallpapered to match the wall. However, keep the small gap around the outer edge clear of any obstructions.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS with a 2-Series control system upgrade file (CUZ) version prior to 3.008, but can be used with later versions of firmware and requires that a single unit be the only network device connected to the control system. Method B (Touch Settable IDs), which begins on the next page, applies to C2N-RTHSs in a Cresnet system with 2-Series control system upgrade file (CUZ) version 3.029 or later.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor 10. Repeat this procedure for each C2N-RTHS to be added to the system. Method B (Touch Settable IDs) Touch Settable ID (TSID) modes are supported through the use of the pinhole setup button and a red LED. These procedures are for TSIDenabled network devices during the initial configuration of a Cresnet system or when such devices are being added/replaced.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS found. The list is similar to the report produced by pressing F4 (Report Network Devices); the first eight digits of each line constitute the TSID number (hexadecimal form of the serial number). 5. As you enter either the serial number or TSID number of the device that requires a change, the corresponding TSID or serial number automatically appears in its appropriate field, and the list scrolls to and highlights the device listing.
Crestron C2N-RTHS 3. Remote Temperature/Humidity Sensor Enter the serial number or TSID number as instructed; press the appropriate button to obtain the corresponding number. NOTE: Enter serial numbers, including spaces, exactly as they appear on the unit label. Alpha characters in serial numbers or TSID numbers may be entered in upper or lower case.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS Programming with SIMPL Windows NOTE: The following are acceptable file extensions for programs that include a C2N-RTHS, developed for specific control system types: .smw projectname.smw (source file) .spz projectname.spz (compiled file for 2-Series) .bin projectname.bin (compiled file for CNX generation) .csz projectname.csz (compiled file for CNX generation with SIMPL+) .ush projectname.ush (compiled file for CNX generation with SIMPL+header file) .
Crestron C2N-RTHS Remote Temperature/Humidity Sensor The System Views lower pane displays the PRO2 system tree (refer to graphic below). This tree can be expanded to display and configure the communications ports. Expanded PRO2 System Tree C2Net Device Slot in Configuration Manager To incorporate a C2N-RTHS into the system, drag the C2N-RTHS from the Cresnet Control Modules | Cresnet Sensing Modules folder of the Device Library and drop it in System Views.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS Setting the Net ID in Device Settings Double-click the C2N-RTHS icon to open the “Device Settings” window. This window displays the C2N-RTHS device information. If necessary, select the Net ID tab to change the C2N-RTHS Net ID, as shown in the following figure.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor C2N-RTHS Digital Input and Analog Output Signals Signal Analog/Digital Function TempInDegreesC Temp Humidity Digital Value Determines temperature output units 1 = Degrees Celsius Analog (signed)* Temperature in tenths of a degree (ex. 723 = 72.3°F) -400 to 1760 °F Analog Relative Humidity in percent (ex.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS NOTE: The Crestron Viewport is available as a pull-down command from SIMPL Windows and VT Pro-e (Tools | Viewport) or as a standalone utility. The Viewport utility accomplishes multiple system tasks, primarily via an RS-232 or TCP/IP connection between the control system and a PC.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor Typical Connection Diagram when Uploading NOTE: Use a standard DB9 male to female “Straight-Through” cable. 1. Open the Crestron Viewport. Either launch the stand-alone version of Viewport, or start SIMPL Windows and from the menu bar, select Tools | Viewport. 2. Refer to the figure after this step. From the Viewport menu, select Setup | Communications settings (alternatively, press Alt+D) to open the “Port Settings” window.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS “Port Settings” Window NOTE: The parameters shown in the illustration above are the port settings for a 2-Series control system. 4. To verify communication, select Diagnostics | Establish Communications (Find Rack). This should display a window that gives the COM port and baud rate. If communication cannot be established, refer to the “Troubleshooting Communications” section in the latest version of the 2-Series Control System Reference Guide (Doc.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor To upgrade the firmware, complete the following steps. NOTE: Viewport versions 3.80 or later have "Load Network Device (Legacy)..." and "Update Network Device Firmware..." options. Either will work with firmware version 3.05 but Crestron suggests using "Update Network Device Firmware..." to load firmware updates. NOTE: A firmware upgrade file has the extension .csf. The following is the acceptable file extension for a firmware update file. .
Remote Temperature/Humidity Sensor Crestron C2N-RTHS “Select Network ID” Window NOTE: If problems arise when transferring any Cresnet file (touchpanel project/firmware), lower the port speed baud rate to 38400 to match the Cresnet bus speed. “Open” Window 4. Browse to the desired [filename] .upg file and click Open to begin the transfer. 20 • Remote Temperature/Humidity Sensors Operations & Installation Guide – DOC.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. C2N-RTHS Troubleshooting TROUBLE No temperature or humidity reading. PROBABLE CAUSE(S) Wiring not properly connected. Improper Cresnet ID. Improper programming. CORRECTIVE ACTION Check connection, refer to page 4. Check Cresnet ID, refer to page 7.
Remote Temperature/Humidity Sensor Crestron C2N-RTHS Future Updates As Crestron improves functions, adds new features, and extends the capabilities of this product, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron website periodically for manual update availability and its relevance.
Crestron C2N-RTHS Remote Temperature/Humidity Sensor Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations & Installation Guide – DOC. 6232A (2009412) 04.05 Specifications subject to change without notice.