User Guide
2-Series Professional Media Controller with RF Crestron MC2W
Physical Views of the MC2W
17.03 in
(43.24 cm)
1.70 in
(4.32 cm)
8.50 in
(21.59 cm)
Controls and Indicators
The MC2W front panel indicators and controls are described below.
PWR (Power)
This LED illuminates when the unit is connected to and receives 24 VDC power
from an external power pack or the Cresnet NET connector.
NET
This LED illuminates when the central processing unit is processing or
communicating with Cresnet devices (i.e., button pressed at Cresnet panel or data
received from Cresnet panel).
HW-R
Pressing this button initiates system hardware reset. (Same effect as disconnecting
and reconnecting power.)
SW-R
Pressing this button in combination with the HW-R button performs a system restart
without loading the program (refer to “Troubleshooting Communications” on page
16). Pressing it alone while the system is running restarts the program without
rebooting the processor.
ERR
This LED illuminates when an error condition is detected. This may be the result of
hardware or software failure, or a programming error. To determine the actual error
condition, examine the message available through the Crestron Viewport command
Functions | 2-Series | Error Log.
4 • 2-Series Professional Media Controller with RF: MC2W Operations Guide - DOC. 6143