Specifications

Crestron PSPHD PROCISE 7.3 Surround Sound Processor
Operations Guide DOC. 6837C PROCISE 7.3 Surround Sound Processor: PSPHD 45
“CONTROL SETUP” Screen (IP)
CONTROL SETUP
03
SOURCE
MODE SETUP
INFO
3. Turn the selection knob to display the desired setting and press the selection
knob to enable the setting and return to the “CONTROL SETUP” menu.
NOTE: If an IP ID is set, Cresnet communications with the PSPHD are
disabled.
For more information on assigning IP IDs, refer to “Identity Codewhich starts on
page 24.
IP Table
The PSPHD uses an IP table for TCP/IP communication with a Crestron control
system. The IP table contains the IP address or hostname of the Crestron control
system that is communicating with the PSPHD. To specify the control system:
1. Open the “CONTROL SETUP” menu as described on page 43.
2. Turn the selection knob until the PSPHD’s IP table entry is displayed. Press
the selection knob to display the IP Table Format screen.
IP Table Format Screen
CONTROL SETUP
IP Table Entry Currently Uses an IP Address
Choose A Format To Overwrite It
IP Address Hostname
SOURCE MODE
SETUP
INFO
3. The control system can be specified by IP address or a hostname. To
specify the control system by:
IP Address:
a. Turn the selection knob to highlight IP Address and press the
selection knob. The “Control System IP Address” screen is
displayed with the first octet of the control system’s IP address
enclosed in brackets.