Specifications

1-Way Wireless RF Touchpanel Crestron ST-1700C
“Device Settings” Window for the CNRFGWA
NOTE: Recall that if the CNRFGWA is part of an ST-CP configuration, its Net ID
is fixed at 02 and cannot be changed.
Similarly, expand the system tree in the lower pane and double-click the ST-1700C
icon to open the “Device Settings” window for the touchpanel. Select the RF/IR ID
tab to change the touchpanel RF ID, as shown in the following figure. For more
information on setting the RF/IR ID, refer to “Select Interface” on page 8.
NOTE: The hardware and software settings of the RF ID must match. Although the
device setting window in SIMPL Windows allows choices through the range of two-
digit Hexadecimal numbers from 01 through FE, the RF ID setting for the hardware
is limited to numbers in increments of the most significant digit (i.e., 00, 10, 20).
Since 00 is not a valid selection in SIMPL Windows, the RF ID number is limited to
the fifteen numbers 10, 20, 30, 40, . . .F0.
Touchpanel “Device Settings” Window
ST-1700C Symbol in Programming Manager
Programming Manager is where programmers “program” a Crestron control system
by assigning signals to symbols. The following diagram shows the ST-1700C
symbol in the SIMPL Windows’ Programming Manager.
14 1-Way Wireless RF Touchpanel: ST-1700C Operations Guide – DOC. 6225A