4. Slide the top cover toward the back panel while holding the ST-LT in
place until the cover is free.
5. Locate the dip switch and notice the orientation (#1 - #8); refer to
illustration below.
Location of Dip Switch on ST-LT PC Board
7
8
6
5
2
3
4
1
O
N
SW2
ST-LT PORTS
ST-LT LEDS
DETAIL OF
8-POSITION
DIP SWITCH
6. Refer to the table below for the dip switch settings for your particular
application. Move the appropriate switch to the ON position to enable
the desired function described in the table.
Dip Switch Functional Description for GRAFIK Eye Use
SWITCH FUNCTION DESCRIPTION
1 Zone Lock Retain
Zone locked units will remain in zone lock after a
power outage.
2 Scene Lock Retain
Scene locked units will remain in scene lock after a
power outage.
3 Sequence Retain
Sequencing units will again sequence after a power
outage.
4 Sequence Type
ON: Sequence scenes 5 - 16
OFF: Sequence scenes 1 - 4
5 Not Used
6 Raw Feedback
Unit will inform RS232 link when any button is
pushed on a GRAFIK Eye main unit or accessory.
7 Scene Status
Unit will inform RS232 link when a new scene is
selected.
8 Not Used
7. Replace the cover by sliding it over the unit and secure with four
screws and washers.
8. Apply power to the ST-LT.