Specifications

Current Sensor Module Crestron ST-CS
Specifications
The following table provides a summary of specifications for the ST-CS module.
ST-CS Specifications
SPECIFICATION DETAILS
Power Requirements 3 Watts (.25A @ 24VDC) - Cresnet
or 0.5A @ 12 VDC external power supply
(PW-1205 supplied with ST-CS, PWI-1210
supplied with STI-CS)
Default Net ID 18
Control System Update Files
1, 2, 3
2-Series Control System Version C2-2.000.CUZ or later
CEN/CN-TVAV
CNMSX-AV/Pro
Version 5.10.13V.UPZ or later
Version 5.01.35X.UPZ or later
CNRACKX/-DP Version 5.01.35W.UPZ or later
ST-CP Version 4.02.04S.UPZ or later
Maximum AC Load 10 A, 1 KW @ 120 VAC (ST-CS)
6 A, 1 KW @ 220 VAC (STI-CS)
Minimum AC Load 0.033 A, 4 W @ 120 VAC
Voltage Range 0 to 220 VAC, 45 to 65 Hz
Ports/Connectors
NET
POWER A
Two 6-pin, RJ type connectors
One 3-pin AC connector (ST-CS)
One 3 conductor, six-foot cable (STI-CS)
POWER B One 3-pin AC connector (ST-CS)
One 3 conductor, six-foot cable (STI-CS)
12 VDC, 0.5A One – Male receptacle for external power pack
POWER IN One 3-conductor cable
Rack Space 1 unit high, ½ unit wide
Environmental Temperature 41° to 113°F (5° to 45°C)
Environmental Humidity 10% to 90% RH (non-condensing)
Dimensions & Weight Height:
Width:
Depth:
Weight:
1.70 in (4.318 cm)
7.07 in (17.95 cm)
6.32 in (16.06 cm)
2.72 lb (1.23 kg) ST-CS
2.96 lb (1.34 kg) STI-CS
1. The latest software versions can be obtained from the Downloads | Software Updates section of the
Crestron website (www.crestron.com
). Refer to the note below.
2. Crestron 2-Series control systems include the AV2, CP2/CP2E, MP2/MP2E, PAC2, PRO2, QM-
RMC, QM-RMCRX and RACK2.
3. Filenames for CNX and ST-CP update files have a UPZ extension. Files on the website may be .zip
or self-extracting .exe files containing the .cuz or .upz file. To avoid program problems, make sure
you are using the update file with the correct suffix letter (e.g., S, V, W, X).
NOTE: Crestron software and any files on the website are for Authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).
2 Current Sensor Module: ST-CS Operations Guide - DOC. 5677A