This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. © 2003 Crestron Electronics, Inc.
Crestron ST-VS Video Sensor Module Contents Video Sensor Module: ST-VS 1 Introduction ............................................................................................................................... 1 Features and Functions................................................................................................ 1 Specifications .............................................................................................................. 1 Physical Description.......................
Crestron ST-VS Video Sensor Module Video Sensor Module: ST-VS Introduction Features and Functions The Crestron® video sensor, ST-VS, is used to detect the presence of a video signal coming out of the baseband video port (typically the yellow RCA or BNC output jack on an A/V device) for up to four independent sources (i.e., VCRs or TVs). The ST-VS detects video with minimum peak-to-peak amplitude of 0.5 VDC (sync to white level). It can also accept audio signals up to 2 Vrms.
Video Sensor Module Crestron ST-VS ST-VS Specifications (continued) SPECIFICATION Control System Update Files DETAILS 1, 2, 3 2-Series Control System Version C2-2.000.CUZ or later CEN/CN-TVAV Version 5.10.13V.UPZ or later CNMSX-AV/PRO Version 5.01.35X.UPZ or later CNRACKX/-DP Version 5.01.35W.UPZ or later ST-CP Version 4.02.04S.UPZ or later Ports/Connectors NET Two 6-pin, RJ type connectors VIDEO 1 through 4 Four pair of RCA Type connectors 12 VDC, 0.
Crestron ST-VS Video Sensor Module ST-VS Front and Rear View ST-VS Physical Views CRESTRON ELECTRONICS INC. ROCKLEIGH, N.J. 07647 6.94 in (17.63 cm) 1.50 in (3.81 cm) 6.13 in (15.58 cm) 6.32 in (16.06 cm) 7.07 in (17.95 cm) VIDEO SENSOR 1.78 in (4.52 cm) PWR NET CRESTRON Operations Guide – DOC.
Video Sensor Module Crestron ST-VS Ports A number of ports are provided on the back of the ST-VS. Each has a silk-screened label. Refer to the illustration and descriptions below. ST-VS Ports CRESTRON ELECTRONICS INC. ROCKLEIGH, N.J. 07647 12 VDC .5A NOTE: If the ST-VS is part of the Cresnet system, use of this port is optional. This DC power socket connector is used to supply power via an external AC power pack. Crestron recommends and supplies specific power packs for its network devices.
Crestron ST-VS Video Sensor Module NOTE: Most 4-conductor phone cables are wired in a crisscross fashion and are not compatible with Crestron equipment. If the power pack is attached when the module is part of a Cresnet system, power is drawn from the power pack. The module does not draw from the network power, but the network power remains chained. VIDEO 1 - 4 There are four sets of independent video pass through connectors.
Video Sensor Module Crestron ST-VS Setup Identity Code All equipment and user interfaces within the network require a unique identity code (Net ID). These codes are two-digit hexadecimal numbers from 03 to FE. The Net ID of each unit must match an ID code specified in the SIMPL Windows program. Refer to “Setting the Net ID in Device Settings” on page 10 for details of the SIMPL Windows procedure. Refer to the note on page 11 for a definition of Viewport.
Crestron ST-VS Video Sensor Module NOTE: When installing network wiring, refer to the latest revision of the wiring diagram(s) appropriate for your specific system configuration, available from the Downloads | Product Manuals | Wiring Diagrams section of the Crestron website (www.crestron.com). NOTE: Refer to the latest revision of the Crestron Network Modular Cable Requirements (Doc. 5682) when making connections to the port labeled NET.
Video Sensor Module Crestron ST-VS Earliest Version Software Requirements for the PC NOTE: Crestron recommends that you use the latest software to take advantage of the most recently released features. The latest software is available from the Downloads | Software Updates section of the Crestron website (www.crestron.com). The following are the earliest useable software version requirements for the PC: • SIMPL Windows, any version. Requires SIMPL+ Cross Compiler version 1.1. • Crestron Database version 15.
Crestron ST-VS Video Sensor Module The System Views lower pane displays the PRO2 system tree (refer to the following graphic). This tree can be expanded to display and configure the communication ports. Expanded PRO2 System Tree C2Net-Device Slot in Configuration Manager To incorporate an ST-VS into the system, drag the ST-VS from the Cresnet Control Modules | Cresnet Sensing Modules folder of the Device Library and drop it in System Views.
Video Sensor Module Crestron ST-VS Setting the Net ID in Device Settings Double-click the ST-VS icon to open the “Device Settings” window. This window displays the ST-VS device information. If necessary, select the Net ID tab to change the Net ID as shown in the following figure. ST-VS “Device Settings” Window NOTE: SIMPL Windows automatically changes the Net ID values of a device added to a program if a duplicate device or a device with the same default Net ID already exists in the program.
Crestron ST-VS Video Sensor Module Device Extenders To facilitate network functions and diagnostics, SIMPL Windows provides two device extenders for the ST-VS. The Poll Manager and The Poll Manager (2 Series Extended) symbols are device extenders for plug-in control cards and for Cresnet devices and touchpanels. The Poll Manager takes the device on and offline without need to physically disconnect it from the network, and reports the current connection status of the device.
Video Sensor Module Crestron ST-VS The procedure in this section provides details for RS-232 communication between the PC and the control system. If TCP/IP communication is preferred, consult the latest version of the Crestron e-Control Reference Guide (Doc. 6052) or the respective Operations Guide for the control system. These documents are available from the Downloads | Product Manuals section of the Crestron website (www.crestron.com).
Crestron ST-VS Video Sensor Module 3. Select RS-232 as the connection type. Verify that an available COM port (COM 1 is shown after this step) is selected, and that all communication parameters and necessary options from the “Port Settings” window are selected as shown after this step. Click the OK button to save the settings and close the window. “Port Settings” Window NOTE: The parameters shown in the illustration above are the port settings for a 2-Series control system.
Video Sensor Module Crestron ST-VS Upload via Crestron Viewport 1. Verify that the procedure for “Communication Settings” that begins on page 11 has been performed. 2. As shown after this step, select File Transfer | Send Program (Alternatively, press Alt+P) from the Viewport menu. File transfer | Send Program Command 3. The “Send Program” window appears as shown after this step. Click Browse, locate the completed file (.spz for PRO2) and click Open.
Crestron ST-VS Video Sensor Module Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. ST-VS Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Unexpected response from control system. Network devices are From the Viewport, poll the network (F4) not communicating to verify communication. to the control system.
Video Sensor Module Crestron ST-VS Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions, please take advantage of the Crestron award winning customer service team by calling: • In the US and Canada, call the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. • In Europe, call Crestron International at +32-15-50-99-50. • In Asia, call Crestron Asia at +852-2341-2016.
Crestron ST-VS Video Sensor Module Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number, and return address. 2.
Video Sensor Module Crestron ST-VS This page intentionally left blank. 18 • Video Sensor Module: ST-VS Operations Guide – DOC.
Crestron ST-VS Video Sensor Module This page intentionally left blank. Operations Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 5767A 12.03 Specifications subject to change without notice.