Specifications
Two-Way RF Transceiver Crestron STRFGWX
4. In the “Set Network ID” dialog box, select the STRFGWX from the
Current Network Devices text window.
CAUTION: If changing the default NET ID, do NOT set the NET ID to 1B or the
unit will have to be returned to Crestron.
5. From the Choose the new network ID for the selected device (Hex): text
box select the new Net ID for the STRFGWX.
6. Click Set ID to initiate the change. This will display the “ID command
has been sent” dialog box.
7. In the “Command Complete” dialog box, click OK.
8. In the Current Network Devices text window, verify the new NET ID
code.
9. In the “Set Network ID” dialog box, click Close.
NOTE: The new NET ID code may also be verified by selecting Diagnostic |
Report Network Devices in the Viewport.
10. Repeat this procedure for each STRFGWX to be added to the Cresnet
system.
RF Channel
Each STRFGWX communicating to a STX-1550C touchpanel must have a RF
CHANNEL that matches the RF CHANNEL of the touchpanel. There are 16
possible channels ranging from 0 to F (hexadecimal number). The same channel may
be used for more than one STRFGWX when used to expand the roaming capabilities
of a touchpanel within any particular area(s) or installation.
The RF channel is set from a PC via SIMPL Windows or VT Pro-e but the method
for changing the unit’s RF channel is identical regardless of the software chosen.
Complete the following steps to set the RF channel.
1. Attach one of the STRFGWXs to the control system (verify that the
software is running).
2. From the SIMPL Windows or VT Pro-e menu, select Tools | Viewport
to open the Crestron Viewport.
3. From the Viewport menu, select Functions | Set RFGWX Channel.
The software checks the baud rate and then opens the “RFGWX
Channel ID” dialog box.
4. In the top-portion of the “RFGWX Channel ID” dialog box, select the
NET ID of the STRFGWX that requires the RF channel set.
5. In the bottom-portion of the “RFGWX Channel ID” dialog box, select
the desired RF channel then click OK.
6. In the “Success” window, click OK.
7. From the Viewport menu, select Diagnostics | Report Network
Devices and verify that the unit has the desired RF channel.
8. Repeat this procedure for each STRFGWX to be added to the Cresnet
system.
8 • Two-Way RF Transceiver: STRFGWX Operations Guide - DOC. 5811A