Specifications
2-Way RF Wireless Touchpanel  Crestron STX-1700C  
The System Views lower pane displays the PRO2 system tree as shown below. This 
tree can be expanded to display and configure the communications ports. 
Expanded PRO2 System Tree 
C2Net-Device Slot in Configuration Manager 
To incorporate an STX-1700C into the system, a gateway device is required. The 
C2Net-Device Slot can accept a gateway such as the STRFGWX. Once a gateway is 
configured in a C2Net-Device Slot, the slot allows Cresnet communication between 
the touchpanel and the control system. 
In Configuration Manager, drag the STRFGWX gateway from the Wireless 
Receivers (RF) folder of the Device Library and drop it in the upper pane of the 
System Views. The System Views upper pane displays the STRFGWX device icon 
below the PRO2 graphic. 
Drag the STX-1700C from the Touchpanels (Wireless | Wireless Two-Way) folder 
of the Device Library and drop it on the STRFGWX symbol in System Views. The 
PRO2 system tree displays the STRFGWX gateway in Slot 9, with a default Net ID 
of 4F. The STRFGWX displays the touchpanel at the touchpanel’s default RF ID 
location, “01,” as shown in the graphic below. 
C2Net Device, Slot 9 
Double-click the STRFGWX icon in the upper pane to open the “Device Settings” 
window. This window displays STRFGWX device information. Select the Net ID 
tab to change the gateway Net ID, as shown in the following graphic. 
14 • 2-Way RF Wireless Touchpanel: STX-1700C  Operations Guide - DOC. 6226A 