Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Operations Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2006 Crestron Electronics, Inc.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Contents CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW 1 Introduction......................................................................................1 Features & Functions.............................................................1 Specifications.........................................................................2 Physical Description ..............................................................4 Industry Compliance...........
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Introduction Features & Functions • CAT5 Balanced AV Interface Wall Plate for Isys® TPS and TPMC-CH touchpanels* • Mounts in a 2-gang electrical box • Uses CresCAT™-D cable to carry Cresnet®, bidirectional audio, and video signals up to 500 feet • Carries 24 Volts DC power to touchpanels that require power from the NET connector • Supports composite, S-video, and component video • Connects to con
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW Specifications Specifications for the TPMC-CH-IMW are listed in the following table.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate TPMC-CH-IMW Specifications (continued) SPECIFICATION Power Requirements Cresnet Power Usage Environmental Temperature Humidity Enclosure Dimensions Height Width Depth Weight Operations Guide – DOC. 6448 DETAILS 2 Watts (0.08 Amps @ 24 Volts DC) 41° to 122°F (5° to 50°C) 10% to 90% RH (non-condensing) 2-gang mountable in a standard electrical box (2.5 inch deep minimum).
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW Physical Description This section provides information on the connections and indicators available on your TPMC-CH-IMW. Physical View of the TPMC-CH-IMW, Front 4 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Operations Guide – DOC.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Physical View of the TPMC-CH-IMW, Rear Operations Guide – DOC.
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW TPMC-CH-IMW Overall Dimensions (Clockwise from top – Front, Side, Rear) 3.50 in (8.89 cm) 1 2 3 1.66 in (4.22 cm) 1.49 in (3.78 cm) 4 4.11 in (10.44 cm) 5 6 7 8 6 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Operations Guide – DOC.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Connectors, Controls, & Indicators # CONNECTORS, CONTROLS, & INDICATORS DESCRIPTION 1 VIDEO 9-pin terminal block connector for twisted pair wiring of balanced or unbalanced video signals to the touchpanel.
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW Connectors, Controls, & Indicators (continued) # CONNECTORS, CONTROLS, & INDICATORS DESCRIPTION 3 NET 4-pin terminal block connector for data and power. Interface connector for the Cresnet connector is provided. Pin 1: (24) Power Pin 2: (Y) Data Pin 3: (Z) Data Pin 4: (G) Ground 5-pin terminal block connector for twisted pair wiring of balanced or unbalanced audio signals from the touchpanel.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Connectors, Controls, & Indicators (continued) # CONNECTORS, CONTROLS, & INDICATORS DESCRIPTION 7 NET 4-pin terminal block connector for data and power. Interface connector for the Cresnet connector is provided. Pin 1: (24) Power Pin 2: (Y) Data Pin 3: (Z) Data Pin 4: (G) Ground RJ-45 connector uses CAT5 wire to provide video input to the touchpanel.
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW Industry Compliance As of the date of manufacture, the TPMC-CH-IMW has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. NOTE: This device complies with part 15 of the FCC rules.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Setup Network Wiring When wiring the network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (http://www.crestron.com/calculators).
CAT5 Balanced AV Interface Wall Plate Connect the Device Crestron TPMC-CH-IMW Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 11 before attaching the 4-position terminal block connector. Apply power after all connections have been made.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate If a video signal is not going to be connected, leave the connector with the jumpers attached to the VIDEO connector. Mount in Electrical Box The TPMC-CH-IMW mounts into a 2-gang electrical box (recommended 2.5" depth). Verify that the unit is mounted into the electrical box as shown in the following diagram. Secure the TPMC-CH-IMW to the electrical box with the four #6-32 flat-head slotted screws (supplied).
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW Orientation of the Insert Plates Connect to Connect the TPMC-CH-IMW to the touchpanel as shown in the the following diagram using the triamese cable supplied with the Touchpanel touchpanel. The triamese cable has labels indicating the port to connect.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPMC-CH-IMW Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Touchpanel does not function. Touchpanel is not receiving power. Touchpanel is not communicating to the network. Improper video connection.
CAT5 Balanced AV Interface Wall Plate Calculate Power Crestron TPMC-CH-IMW CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. CAUTION: Provide sufficient power to the system. Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (http://www.crestron.com/calculators).
Crestron TPMC-CH-IMW Add Hubs CAT5 Balanced AV Interface Wall Plate For larger networks (i.e., greater than 28 network devices), it may become necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality throughout the network. Also, for networks with lengthy cable runs, it may be necessary to add a Hub/Repeater after only 20 devices. Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website (http://www.crestron.
CAT5 Balanced AV Interface Wall Plate Crestron TPMC-CH-IMW Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.
Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate . This page intentionally left blank. Operations Guide – DOC.
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide – DOC. 6448 (2014256) 03.06 Specifications subject to change without notice.