Crestron TPS-17G-QM/-L-IMC Power Interface Module Contents Power Interface Module: TPS-17G-QM/-L-IMC 1 Introduction ............................................................................................................................... 1 Specifications .............................................................................................................. 1 Physical Description....................................................................................................
Crestron TPS-17G-QM/-L-IMC Power Interface Module Power Interface Module: TPS-17G-QM/-L-IMC Introduction The Crestron® TPS-17G-QM/-L-IMC is a power interface module that is included with the TPS-17G-QM and TPS-17G-QM-L touchpanels. It is a passive device designed to facilitate the remote placement of the touchpanel’s power supply up to 80 feet (24 meters) from the touchpanel using standard Cresnet® control wire.
Power Interface Module Crestron TPS-17G-QM/-L-IMC TPS-17G-QM/-L-IMC Specifications (Continued) SPECIFICATION Dimensions Height Width Depth Weight Included Accessories PW-2435RU DETAILS 1.06 in (2.68 cm) 3.43 in (8.70 cm) 2.08 in (5.28 cm) 4.9 oz (138.9 kg) 24 Volt Power Pack Physical Description This section provides information on the connections, controls and indicators available on your TPS-17G-QM/-L-IMC.
Crestron TPS-17G-QM/-L-IMC Power Interface Module TPS-17G-QM/-L-IMC Overall Dimensions (Top View) 3.43 in (8.70 cm) 2.98 in (7.57 cm) 2.08 in (5.28 cm) 1.25 in (3.18 cm) TPS-17G-QM/-L-IMC Overall Dimensions (Front View) 0.98 in 1.06 in (2.49 cm) (2.68 cm) 1 Operations Guide – DOC.
Power Interface Module Crestron TPS-17G-QM/-L-IMC Connectors, Controls & Indicators * # CONNECTORS*, CONTROLS & INDICATORS DESCRIPTION 1 PWR IN 24 VDC 3.5A 2 NET IN 3 NET OUT (1) 2.
Crestron TPS-17G-QM/-L-IMC Power Interface Module Industry Compliance As of the date of manufacture, the TPS-17G-QM/-L-IMC has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC rules.
Power Interface Module Crestron TPS-17G-QM/-L-IMC Setup Network Wiring When wiring the Cresnet network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www.crestron.com/calculators).
Crestron TPS-17G-QM/-L-IMC Power Interface Module Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 6 before attaching the 4-position terminal block connector. Apply power after all connections have been made. When making connections to the TPS-17G-QM/-L-IMC, use Crestron power supplies for Crestron equipment. Hardware Connections for the TPS-17G-QM/-L-IMC PWR IN 24 VDC 3.
Power Interface Module Crestron TPS-17G-QM/-L-IMC Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. TPS-17G-QM/-L-IMC Troubleshooting TROUBLE Touchpanel does not function. POSSIBLE CAUSE(S) CORRECTIVE ACTION Touchpanel is not communicating with the network. Use Crestron Toolbox™ to poll the network. Verify network connection to the device.
Crestron TPS-17G-QM/-L-IMC Power Interface Module Check Network Wiring Use the Right Wire Calculate Power In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies because of using improper wire. CAUTION: Use only Crestron power supplies for Crestron equipment.
Power Interface Module Crestron TPS-17G-QM/-L-IMC NOTE: All Crestron certified Cresnet wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pair is the Y conductor and the Z conductor. Strip and Tin Wire When daisy-chaining Cresnet units, strip the ends of the wires carefully to avoid nicking the conductors. Twist together the ends of the wires that share a pin on the network connector and tin the twisted connection.
Crestron TPS-17G-QM/-L-IMC Power Interface Module Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number.